EUVIMEDEUVIMED entdecken
Crossref

Cyclic Mechanism Affects Lumbar Spine Creep Response

Elizabeth D Dimbath, Concetta Morino, Shea Middleton, Jason Kait, Maria Ortiz-Paparoni, Theodore A Slotkin, Jason F Luck, Cameron R 'Dale' Bass

Annals of Biomedical Engineering · 2024

DOI: 10.1007/s10439-024-03595-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von Elizabeth D Dimbath und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Duke University, 101 Science Dr, 1427 FCIEMAS Bldg, Box 90281, Durham, NC, 27708, USA. elizabeth.dimbath@duke.e…. Hauptthemen laut MEDLINE: Lumbar Vertebrae. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Office of Naval Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aims to explore how cyclic loading influences creep response in the lumbar spine under combined flexion-compression loading. METHODS: Ten porcine functional spinal units (FSUs) were mechanically tested in cyclic or static combined flexion-compression loading. Creep response between loading regimes was compared using strain-time histories and linear regression. High-resolution computed tomography (µCT) visualized damage to FSUs. Statistical methods, ANCOVA and ANOVA, assessed differences in behavior between loading regimes. RESULTS: Cyclic and static loading regimes exhibited distinct creep response patterns and biphasic response. ANCOVA and ANOVA analyses revealed significant differences in slopes of creep behavior in both linear phases. Cyclic tests consistently showed endplate fractures in µCT imaging. CONCLUSION: The study reveals statistically significant differences in creep response between cyclic and static loading regimes in porcine lumbar spinal units under combined flexion-compression loading. The observed biphasic behavior suggests distinct phases of tissue response, indicating potential shifts in load transfer mechanisms. Endplate fractures in cyclic tests suggest increased injury risk compared to static loading. These findings underscore the importance of considering loading conditions in computational models and designing preventive measures for occupations involving repetitive spinal loading.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lumbar VertebraeAnimalsSwineWeight-BearingStress, MechanicalBiomechanical PhenomenaX-Ray MicrotomographyCompressive Strength

Stichwörter der Autor:innen

Combined loadingCreep responseCyclic loadingLumbar spineMechanical testing

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Duke University, 101 Science Dr, 1427 FCIEMAS Bldg, Box 90281, Durham, NC, 27708, USA. elizabeth.dimbath@duke.edu.
  • Department of Biomedical Engineering, Duke University, 101 Science Dr, 1427 FCIEMAS Bldg, Box 90281, Durham, NC, 27708, USA.
  • Department of Mechanical Engineering and Material Science, Duke University, Durham, NC, 27708, USA.
  • Department of Pharmacology and Cancer Biology, Duke University School of Medicine, Durham, NC, 27710, USA.
  • Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA.

Förderung

  • Office of Naval Research

Zitieren

APA

Dimbath, E. D., Morino, C., Middleton, S., Kait, J., Ortiz-Paparoni, M., Slotkin, T. A., Luck, J. F., & Bass, C. R. (2024). Cyclic Mechanism Affects Lumbar Spine Creep Response. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03595-w

Vancouver

Dimbath ED, Morino C, Middleton S, Kait J, Ortiz-Paparoni M, Slotkin TA, et al. Cyclic Mechanism Affects Lumbar Spine Creep Response. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-024-03595-w

BibTeX
@article{Dimbath2024,
  author = {Dimbath, Elizabeth D and Morino, Concetta and Middleton, Shea and Kait, Jason and Ortiz-Paparoni, Maria and Slotkin, Theodore A and Luck, Jason F and Bass, Cameron R 'Dale'},
  title = {Cyclic Mechanism Affects Lumbar Spine Creep Response},
  journal = {Annals of Biomedical Engineering},
  year = {2024},
  doi = {10.1007/s10439-024-03595-w}
}
Kostenlos starten →