Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect
Annals of Biomedical Engineering · 2025
DOI: 10.1007/s10439-024-03588-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2025. Verfasst von Sofia Baroni und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy. sofia.baroni2@unibo.it. Hauptthemen laut MEDLINE: Tibia, Osseointegration, Models, Biological, Prosthesis Failure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Alma Mater Studiorum - Università di Bologna.
Abstract (Originalsprache)
The risk of aseptic loosening in cementless hip stems can be reduced by improving osseointegration with osteoinductive coatings favoring long-term implant stability. Osseointegration is usually evaluated in vivo studies, which, however, do not reproduce the mechanically driven adaptation process. This study aims to develop an in silico model to predict implant osseointegration and the effect of induced micromotion on long-term stability, including a calibration of the material osteoinductivity with conventional in vivo studies. A Finite Element model of the tibia implanted with pins was generated, exploiting bone-to-implant contact measures of cylindrical titanium alloys implanted in rabbits’ tibiae. The evolution of the contact status between bone and implant was modeled using a finite state machine, which updated the contact state at each iteration based on relative micromotion, shear and tensile stresses, and bone-to-implant distance. The model was calibrated with in vivo data by identifying the maximum bridgeable gap. Afterward, a push-out test was simulated to predict the axial load that caused the macroscopic mobilization of the pin. The bone-implant bridgeable gap ranged between 50 μm and 80 μm. Predicted push-out strength ranged from 19 N to 21 N (5.4 MPa–3.4 MPa) depending on final bone-to-implant contact. Push-out strength agrees with experimental measurements from a previous animal study (4 ± 1 MPa), carried out using the same implant material, coated, or uncoated. This method can partially replace in vivo studies and predict the long-term stability of cementless hip stems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy. sofia.baroni2@unibo.it.
- Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano1/10, 40136, Bologna, Italy.
- SC Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
- Scientific Direction, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Förderung
- Horizon 2020 Framework Programme
- Alma Mater Studiorum - Università di Bologna
Zitieren
APA
Baroni, S., Oliviero, S., La Mattina, A. A., Maglio, M., Martini, L., Fini, M., & Viceconti, M. (2025). Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03588-9
Vancouver
Baroni S, Oliviero S, La Mattina AA, Maglio M, Martini L, Fini M, et al. Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect. Annals of Biomedical Engineering. 2025. doi:10.1007/s10439-024-03588-9
BibTeX
@article{Baroni2025,
author = {Baroni, Sofia and Oliviero, Sara and La Mattina, Antonino Amedeo and Maglio, Melania and Martini, Lucia and Fini, Milena and Viceconti, Marco},
title = {Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect},
journal = {Annals of Biomedical Engineering},
year = {2025},
doi = {10.1007/s10439-024-03588-9}
}
EUVIMED