Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion
Annals of Biomedical Engineering · 2024
DOI: 10.1007/s10439-024-03517-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von Mingyue Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia. Hauptthemen laut MEDLINE: Range of Motion, Articular, Neck. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hospital Research Foundation, The University of Adelaide.
Abstract (Originalsprache)
Understanding of human neck stiffness and range of motion (ROM) with minimal neck muscle activation (“passive”) is important for clinical and bioengineering applications. The aim of this study was to develop, implement, and evaluate the reliability of methods for assessing passive-lying stiffness and ROM, in six head-neck rotation directions. Six participants completed two assessment sessions. To perform passive-lying tests, the participant’s head and torso were strapped to a bending (flexion, extension, lateral bending) or a rotation (axial rotation) apparatus, and clinical bed, respectively. The head and neck were manually rotated by the researcher to the participant’s maximum ROM, to assess passive-lying stiffness. Participant-initiated (“active”) head ROM was also assessed in the apparatus, and seated. Various measures of apparatus functionality were assessed. ROM was similar for all assessment configurations in each motion direction except flexion. In each direction, passive stiffness generally increased throughout neck rotation. Within-session reliability for stiffness (ICC > 0.656) and ROM (ICC > 0.872) was acceptable, but between-session reliability was low for some motion directions, probably due to intrinsic participant factors, participant-apparatus interaction, and the relatively low participant number. Moment-angle corridors from both assessment sessions were similar, suggesting that with greater sample size, these methods may be suitable for estimating population-level corridors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia.
- Adelaide Spinal Research Group, Centre for Orthopaedic & Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia.
- Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, Paris, France.
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia. claire.jones@adelaide.edu.au.
- Adelaide Spinal Research Group, Centre for Orthopaedic & Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia. claire.jones@adelaide.edu.au.
- Department of Orthopaedics & Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia. claire.jones@adelaide.edu.au.
Förderung
- Hospital Research Foundation
- The University of Adelaide
Zitieren
APA
Liu, M., Quarrington, R. D., Sandoz, B., Robertson, W. S. P., & Jones, C. F. (2024). Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03517-w
Vancouver
Liu M, Quarrington RD, Sandoz B, Robertson WSP, Jones CF. Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-024-03517-w
BibTeX
@article{Liu2024,
author = {Liu, Mingyue and Quarrington, Ryan D and Sandoz, Baptiste and Robertson, William S P and Jones, Claire F},
title = {Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion},
journal = {Annals of Biomedical Engineering},
year = {2024},
doi = {10.1007/s10439-024-03517-w}
}
EUVIMED