Three Sliding Probes Placed on Forelimb Skin for Proprioceptive Feedback Differentially yet Complementarily Contribute to Hand Gesture Detection and Object-Size Discrimination
Annals of Biomedical Engineering · 2024
DOI: 10.1007/s10439-023-03434-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von İsmail Devecioğlu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, Çorlu Faculty of Engineering, Tekirdağ Namık Kemal University, Tekirdağ, Turkey. idevecioglu@nku.edu.tr. Hauptthemen laut MEDLINE: Feedback, Sensory, Gestures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tekirdağ Namık Kemal Üniversitesi, Tekirdag Namık Kemal University.
Abstract (Originalsprache)
The purpose was to assess the effectiveness of three sliding tactile probes placed on the forelimb skin to provide proprioceptive feedback for the detection of hand gestures and discrimination of object size. Tactile contactors representing the first three fingers were driven along the proximodistal axis by linear servo motors. Twenty healthy subjects were involved in the gesture detection test, with 10 of them also participating in the object-size discrimination task. Motors were controlled by computer in the first four sessions of the gesture detection experiment, while the fifth session utilized a sensorized glove. Both the volar and dorsal sides of the forearm were examined. In the object-size discrimination experiment, the method was exclusively assessed on the volar surface under four distinct feedback conditions, including all fingers and each finger separately. The psychophysical data were further analyzed using a structural equation model (SEM) to evaluate the specific contributions of each individual contactor. Subjects consistently outperformed the chance level in detecting gestures. Performance improved up to the third session, with better results obtained on the volar side. The performances were similar in the fourth and fifth sessions. The just noticeable difference for achieving a 75% discrimination accuracy was found to be 2.90 mm of movement on the skin. SEM analysis indicated that the contactor for the index finger had the lowest importance in gesture detection, while it played a more significant role in object-size discrimination. However, all fingers were found to be significant predictors of subjects' responses in both experiments, except for the thumb, which was deemed insignificant in object-size discrimination. The study highlights the importance of considering the partial contribution of each degree of freedom in a sensory feedback system, especially concerning the task, when designing such systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering Department, Çorlu Faculty of Engineering, Tekirdağ Namık Kemal University, Tekirdağ, Turkey. idevecioglu@nku.edu.tr.
- Department of Biomedical Device Technologies, Vocational School of Technical Sciences, Tekirdağ Namık Kemal University, Tekirdağ, Turkey.
Förderung
- Tekirdağ Namık Kemal Üniversitesi
- Tekirdag Namık Kemal University
Zitieren
APA
Devecioğlu, İ., & Karakulak, E. (2024). Three Sliding Probes Placed on Forelimb Skin for Proprioceptive Feedback Differentially yet Complementarily Contribute to Hand Gesture Detection and Object-Size Discrimination. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-023-03434-4
Vancouver
Devecioğlu İ, Karakulak E. Three Sliding Probes Placed on Forelimb Skin for Proprioceptive Feedback Differentially yet Complementarily Contribute to Hand Gesture Detection and Object-Size Discrimination. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-023-03434-4
BibTeX
@article{Deveciolu2024,
author = {Devecioğlu, İsmail and Karakulak, Ertuğrul},
title = {Three Sliding Probes Placed on Forelimb Skin for Proprioceptive Feedback Differentially yet Complementarily Contribute to Hand Gesture Detection and Object-Size Discrimination},
journal = {Annals of Biomedical Engineering},
year = {2024},
doi = {10.1007/s10439-023-03434-4}
}
EUVIMED