Effect of Membrane Permeance and System Parameters on the Removal of Protein-Bound Uremic Toxins in Hemodialysis
Annals of Biomedical Engineering · 2024-03 · 52 (3) · 526-541
DOI: 10.1007/s10439-023-03397-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, online erschienen am 22.11.2023. Verfasst von Chun Man Chow und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Massachusetts Institute of Technology, 25 Ames St, Cambridge, MA, 02142, USA. Hauptthemen laut MEDLINE: Uremia, Toxins, Biological. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dialysis Direct Innovation Lab, National Science Foundation, Croucher Foundation.
Abstract (Originalsprache)
Inadequate clearance of protein-bound uremic toxins (PBUTs) during dialysis is associated with morbidities in chronic kidney disease patients. The development of high-permeance membranes made from materials such as graphene raises the question whether they could enable the design of dialyzers with improved PBUT clearance. Here, we develop device-level and multi-compartment (body) system-level models that account for PBUT-albumin binding (specifically indoxyl sulfate and p -cresyl sulfate) and diffusive and convective transport of toxins to investigate how the overall membrane permeance (or area) and system parameters including flow rates and ultrafiltration affect PBUT clearance in hemodialysis. Our simulation results indicate that, in contrast to urea clearance, PBUT clearance in current dialyzers is mass-transfer limited: Assuming that the membrane resistance is dominant, raising PBUT permeance from 3 × 10 −6 to 10 −5 m s −1 (or equivalently, 3.3 × increase in membrane area from ~ 2 to ~ 6 m 2 ) increases PBUT removal by 48% (from 22 to 33%, i.e., ~ 0.15 to ~ 0.22 g per session), whereas increasing dialysate flow rates or adding adsorptive species have no substantial impact on PBUT removal unless permeance is above ~ 10 −5 m s −1 . Our results guide the future development of membranes, dialyzers, and operational parameters that could enhance PBUT clearance and improve patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Massachusetts Institute of Technology, 25 Ames St, Cambridge, MA, 02142, USA.
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, USA.
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, USA. karnik@mit.edu.
Förderung
- Dialysis Direct Innovation Lab
- National Science Foundation
- Croucher Foundation
- Massachusetts Institute of Technology
Zitieren
APA
Chow, C. M., Persad, A. H., & Karnik, R. (2024). Effect of Membrane Permeance and System Parameters on the Removal of Protein-Bound Uremic Toxins in Hemodialysis. Annals of Biomedical Engineering, 52(3), 526-541. https://doi.org/10.1007/s10439-023-03397-6
Vancouver
Chow CM, Persad AH, Karnik R. Effect of Membrane Permeance and System Parameters on the Removal of Protein-Bound Uremic Toxins in Hemodialysis. Annals of Biomedical Engineering. 2024;52(3):526-541. doi:10.1007/s10439-023-03397-6
BibTeX
@article{Chow2024,
author = {Chow, Chun Man and Persad, Aaron H and Karnik, Rohit},
title = {Effect of Membrane Permeance and System Parameters on the Removal of Protein-Bound Uremic Toxins in Hemodialysis},
journal = {Annals of Biomedical Engineering},
year = {2024},
volume = {52},
number = {3},
pages = {526--541},
doi = {10.1007/s10439-023-03397-6}
}
EUVIMED