Ultrasound-guided biopsy for thoracic lesions: diagnostic performance, safety, and potential role of contrast-enhanced ultrasound

Masato Saito, Hiroki Okuda, Akemi Ohtani, Hiroki Sato, Kenichiro Nitta, Kisara Koike, Masanori Someya

Journal of Medical Ultrasonics · 23.05.2026

DOI: 10.1007/s10396-026-01648-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Ultrasonics, online erschienen am 23.05.2026. Verfasst von Masato Saito und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiation Oncology and Interventional Radiology, Department of Radiology, Sapporo Medical University School of Medicine, South 1, West 16…. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To retrospectively evaluate the diagnostic performance and safety of ultrasound (US)-guided biopsy for thoracic lesions, exploring the potential role of contrast-enhanced US (CEUS) for tissue sampling accuracy. METHODS: This single-center retrospective study included 14 consecutive cases that underwent US-guided biopsy for thoracic lesions. The mean age was 68 ± 12 years (8 males, 6 females). Lesions were located in the lung (n = 3), mediastinum (n = 4), chest wall (n = 3), and rib (n = 4). Biopsies were performed using an 18- or 20-gauge core needle under B-mode and color Doppler guidance. CEUS using Sonazoid® was employed in three cases: two with suspected necrosis and one with renal impairment. The primary outcome measures were technical and clinical success, diagnostic accuracy, and complications. RESULTS: Technical and clinical success rates were both 100% (14/14). Diagnostic accuracy was 92.8% (13/14) with a false-negative rate of 9.1% (1/11 malignant cases). Median biopsies: 2 (range: 1-4); mean procedure time: 24.0 ± 12.5 min. Diagnoses included three benign and 11 malignant lesions. One complication (7.1%) occurred: mild pneumothorax managed conservatively. This case required four biopsies due to necrotic tissue sampling. CEUS-guided cases achieved diagnosis within three biopsies without complications, with successful identification of viable tissue in all cases. CONCLUSION: US-guided biopsy for thoracic lesions demonstrates high success rates and safety comparable to those in the literature. In this limited series, CEUS showed potential for identifying viable tissue in cases with suspected necrosis and enabled lesion evaluation while minimizing iodinated contrast exposure in patients with renal impairment. Validation in larger studies is needed.

Schlagwörter

Stichwörter der Autor:innen

ComplicationsContrast-enhanced ultrasound (CEUS)Thoracic lesionsUltrasound-guided biopsy

Autor:innen und Institutionen

  • Division of Radiation Oncology and Interventional Radiology, Department of Radiology, Sapporo Medical University School of Medicine, South 1, West 16, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan. saitomasa@sapmed.ac.jp.
  • Division of Radiation Oncology and Interventional Radiology, Department of Radiology, Sapporo Medical University School of Medicine, South 1, West 16, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan.

Zitieren

APA

Saito, M., Okuda, H., Ohtani, A., Sato, H., Nitta, K., Koike, K., & Someya, M. (2026). Ultrasound-guided biopsy for thoracic lesions: diagnostic performance, safety, and potential role of contrast-enhanced ultrasound. Journal of Medical Ultrasonics. https://doi.org/10.1007/s10396-026-01648-2

Vancouver

Saito M, Okuda H, Ohtani A, Sato H, Nitta K, Koike K, et al. Ultrasound-guided biopsy for thoracic lesions: diagnostic performance, safety, and potential role of contrast-enhanced ultrasound. Journal of Medical Ultrasonics. 2026. doi:10.1007/s10396-026-01648-2

BibTeX
@article{Saito2026,
  author = {Saito, Masato and Okuda, Hiroki and Ohtani, Akemi and Sato, Hiroki and Nitta, Kenichiro and Koike, Kisara and Someya, Masanori},
  title = {Ultrasound-guided biopsy for thoracic lesions: diagnostic performance, safety, and potential role of contrast-enhanced ultrasound},
  journal = {Journal of Medical Ultrasonics},
  year = {2026},
  doi = {10.1007/s10396-026-01648-2}
}
Kostenlos starten →