Comparing reference points in strain elastography for predicting autoimmune thyroiditis
Journal of Medical Ultrasonics · 2025
DOI: 10.1007/s10396-025-01593-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Medical Ultrasonics, 2025. Verfasst von Yi-Chen Ho und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, MacKay Memorial Hospital, 92, Chung-Shan North Road, Section 2, Taipei, 104217, Taiwan. Hauptthemen laut MEDLINE: Thyroiditis, Autoimmune, Elasticity Imaging Techniques. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Chronic autoimmune thyroiditis shows increased stiffness on elastography. The sternocleidomastoid (SCM) or strap muscles have been used as references in strain elastography in prior studies. We aimed to compare the effects of different reference points in strain elastography on its diagnostic performance. METHODS: Patients referred for thyroidectomy underwent strain elastography assessment of the non-tumor-bearing thyroid parenchyma. The strain ratio was determined using either the adjacent SCM muscle or the trachea at the same depth as reference points. Final pathological results served as the standard. RESULTS: A total of 174 patients were analyzed, with 39 (22%) diagnosed with autoimmune thyroiditis. Multivariate logistic regression identified thyroid peroxidase antibodies, thyroglobulin antibodies, and the strain ratio using the trachea as a reference as independent predictors of thyroiditis. The area under the receiver operating characteristic curve was significantly higher with the trachea as the reference compared to the SCM (0.854 vs. 0.611). Sensitivity analyses indicated that diagnostic performance was not affected by patient age or body habitus. CONCLUSIONS: Different reference points in strain elastography significantly influence the predictability of autoimmune thyroiditis, and using the trachea as a reference improves diagnostic performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, MacKay Memorial Hospital, 92, Chung-Shan North Road, Section 2, Taipei, 104217, Taiwan.
- Department of Medicine, MacKay Medical University, New Taipei City, Taiwan.
- Division of Endocrinology and Metabolism, Department of Internal Medicine, MacKay Memorial Hospital, Taipei, Taiwan.
- Department of Surgery, MacKay Memorial Hospital, 92, Chung-Shan North Road, Section 2, Taipei, 104217, Taiwan. surg.mmh@gmail.com.
- Department of Medicine, MacKay Medical University, New Taipei City, Taiwan. surg.mmh@gmail.com.
- Institute of Biomedical Sciences, MacKay Medical University, New Taipei City, Taiwan. surg.mmh@gmail.com.
Zitieren
APA
Ho, Y. C., Kuo, C. Y., Chien, M. N., & Cheng, S. P. (2025). Comparing reference points in strain elastography for predicting autoimmune thyroiditis. Journal of Medical Ultrasonics. https://doi.org/10.1007/s10396-025-01593-6
Vancouver
Ho YC, Kuo CY, Chien MN, Cheng SP. Comparing reference points in strain elastography for predicting autoimmune thyroiditis. Journal of Medical Ultrasonics. 2025. doi:10.1007/s10396-025-01593-6
BibTeX
@article{Ho2025,
author = {Ho, Yi-Chen and Kuo, Chi-Yu and Chien, Ming-Nan and Cheng, Shih-Ping},
title = {Comparing reference points in strain elastography for predicting autoimmune thyroiditis},
journal = {Journal of Medical Ultrasonics},
year = {2025},
doi = {10.1007/s10396-025-01593-6}
}
EUVIMED