Reliability of liver stiffness measurements using shear wave elastography: impact of skin-to-capsule distance and subcutaneous tissue structure
Journal of Medical Ultrasonics · 2026-04 · 53 (2) · 147-156
DOI: 10.1007/s10396-025-01582-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Ultrasonics, online erschienen am 04.10.2025. Verfasst von Keisuke Osakabe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology, Fujita Health University School of Medical Sciences, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan. …. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver, Skin, Subcutaneous Tissue. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Shear wave velocity (Vs) measurements can be unstable in individuals with obesity or with a skin-capsule distance (SCD) of ≥ 20 mm. However, instability of Vs has also been observed in cases where SCD is not markedly increased; therefore, the present study aimed to investigate the factors contributing to reduced VsN (net amount of effective shear wave velocity), an index that reflects the reliability of individual Vs measurements. METHODS: In total, 317 individuals who underwent community-based health screening were included in this study. We investigated the relationship between VsN and physical findings, laboratory data, SCD, and structure of the SCD (single vs. multilayered) to identify factors associated with decreased VsN. RESULTS: Multiple regression analysis revealed that body fat percentage (β = - 0.135, p = 0.011), SCD (β = - 0.347, p < 0.0001), and the structure of the SC region (β = - 0.295, p < 0.0001) were independently associated with decreased VsN. In cases where the SCD exceeded 20 mm, the VsN within the SCD was significantly lower in the multilayer structural type [52 (28-75)] than in the single-layer structural type [95 (77-99)] (p = 0.004). Furthermore, even when the SCD was 20 mm or less, the VsN within the SCD was significantly lower in the multilayer structure type [80 (68-89)] than in the single-layer structure type [99 (92-100)] (p < 0.0001). CONCLUSION: The results show that, in addition to SCD thickness, its internal structure reduces the VsN and contributes to Vs measurement instability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Physiology, Fujita Health University School of Medical Sciences, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan. kosakabe@fujita-hu.ac.jp.
- Department of Medical Sciences Education, Fujita Health University School of Medical Sciences, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan.
- Department of Clinical Radiology, Fujita Health University Hospital, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan.
- Department of Clinical Laboratory, Fujita Health University Hospital, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan.
- Department of Clinical Physiology, Fujita Health University School of Medical Sciences, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan.
- Department of Preventive Medical Sciences, Fujita Health University School of Medical Sciences, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Japan.
Zitieren
APA
Osakabe, K., Sugimoto, K., Takai, H., Sano, Y., Maeda, K., Suzuki, K., & Ichino, N. (2026). Reliability of liver stiffness measurements using shear wave elastography: impact of skin-to-capsule distance and subcutaneous tissue structure. Journal of Medical Ultrasonics, 53(2), 147-156. https://doi.org/10.1007/s10396-025-01582-9
Vancouver
Osakabe K, Sugimoto K, Takai H, Sano Y, Maeda K, Suzuki K, et al. Reliability of liver stiffness measurements using shear wave elastography: impact of skin-to-capsule distance and subcutaneous tissue structure. Journal of Medical Ultrasonics. 2026;53(2):147-156. doi:10.1007/s10396-025-01582-9
BibTeX
@article{Osakabe2026,
author = {Osakabe, Keisuke and Sugimoto, Keiko and Takai, Hiroji and Sano, Yusuke and Maeda, Keisuke and Suzuki, Koji and Ichino, Naohiro},
title = {Reliability of liver stiffness measurements using shear wave elastography: impact of skin-to-capsule distance and subcutaneous tissue structure},
journal = {Journal of Medical Ultrasonics},
year = {2026},
volume = {53},
number = {2},
pages = {147--156},
doi = {10.1007/s10396-025-01582-9}
}
EUVIMED