Enhancing deep-seated hepatocellular carcinoma detection: assessing the added value of high mechanical index setting in sonazoid-based contrast-enhanced ultrasound during post-vascular phase
Journal of Medical Ultrasonics · 2025
DOI: 10.1007/s10396-024-01507-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Ultrasonics, 2025. Verfasst von Ying Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa, 232-0024, Japan. Hauptthemen laut MEDLINE: Liver Neoplasms, Contrast Media, Carcinoma, Hepatocellular, Ferric Compounds. Die Arbeit nennt 49 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This retrospective study aimed to investigate the role of an additional high mechanical index (MI) setting scan during the post-vascular phase (PVP) in detecting deep-seated hepatocellular carcinoma (HCC) lesions. METHODS: A total of 805 confirmed HCCs, which underwent Sonazoid-based contrast-enhanced ultrasound (CEUS) between January 2014 and October 2021, were included. Low MI scan was initially employed for lesion detection during the PVP, followed by high MI scan. Propensity score matching (PSM) was utilized to address confounding variables. RESULTS: Of the 805 study lesions, 668 were detected as perfusion defects at the initial low MI setting, while 137 remained undetected. Among these 137 undetected lesions, 77 were identified at the subsequent high MI setting, whereas 60 remained undetected. Lesions that were larger (18.69 ± 11.27 mm vs. 16.55 ± 7.42 mm, p = 0.006), more superficial (6.06 ± 2.41 cm vs. 7.40 ± 2.74 cm, p < 0.001), and hypoechoic (482/668 vs. 62/137, p < 0.001) were detectable at the initial low MI setting. Male patients benefited more from the additional high MI scan (63/97 vs. 14/40, p < 0.001). Lesions identified with additional high MI were larger (18.30 ± 8.76 mm vs. 14.30 ± 4.34 mm, p < 0.001) and deeper than undetected ones (8.48 ± 2.48 cm vs. 6.02 ± 2.43 cm, p < 0.001). After PSM, depth was shown to be an independent predictor in multivariate analysis (odds ratio: 1.557, 95% confidence interval: 1.249-1.941). The depth cutoff was 7.75 cm, with a sensitivity of 0.681, specificity of 0.851, and area under the curve of 0.774. CONCLUSIONS: The additional high MI setting scan during the PVP of Sonazoid-based CEUS leads to enhanced detection of deep-seated HCCs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa, 232-0024, Japan.
- Department of Gastroenterology, Yokohama City University Graduate School of Medicine, Yokohama, Japan.
- Department of Medical Ultrasound, Ningbo Medical Center Lihuili Hospital, Ningbo City, China.
- Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa, 232-0024, Japan. kz_numa@yokohama-cu.ac.jp.
- Department of Gastroenterology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan.
Zitieren
APA
Zhang, Y., Numata, K., Nihonmatsu, H., Funaoka, A., Miwa, H., Oishi, R., Nozaki, A., & Maeda, S. (2025). Enhancing deep-seated hepatocellular carcinoma detection: assessing the added value of high mechanical index setting in sonazoid-based contrast-enhanced ultrasound during post-vascular phase. Journal of Medical Ultrasonics. https://doi.org/10.1007/s10396-024-01507-y
Vancouver
Zhang Y, Numata K, Nihonmatsu H, Funaoka A, Miwa H, Oishi R, et al. Enhancing deep-seated hepatocellular carcinoma detection: assessing the added value of high mechanical index setting in sonazoid-based contrast-enhanced ultrasound during post-vascular phase. Journal of Medical Ultrasonics. 2025. doi:10.1007/s10396-024-01507-y
BibTeX
@article{Zhang2025,
author = {Zhang, Ying and Numata, Kazushi and Nihonmatsu, Hiromi and Funaoka, Akihiro and Miwa, Haruo and Oishi, Ritsuko and Nozaki, Akito and Maeda, Shin},
title = {Enhancing deep-seated hepatocellular carcinoma detection: assessing the added value of high mechanical index setting in sonazoid-based contrast-enhanced ultrasound during post-vascular phase},
journal = {Journal of Medical Ultrasonics},
year = {2025},
doi = {10.1007/s10396-024-01507-y}
}
EUVIMED