Efficacy of B-mode ultrasound-based attenuation for the diagnosis of hepatic steatosis: a systematic review/meta-analysis

Masashi Hirooka, Yohei Koizumi, Kotarou Sunago, Yoshiko Nakamura, Kana Hirooka, Takao Watanabe, Osamu Yoshida, Yoshio Tokumoto, Masanori Abe, Yoichi Hiasa

Journal of Medical Ultrasonics · 2022-04 · 49 (2) · 199-210

DOI: 10.1007/s10396-022-01196-5 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Journal of Medical Ultrasonics, online erschienen am 03.03.2022. Verfasst von Masashi Hirooka und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Shitsukawa, Tōon, Ehime, 791-0295, Japan. masashih@m.ehi…. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Fatty Liver. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accuracy of attenuation coefficients and B-mode ultrasound for distinguishing between S0 (healthy, 66%. Nineteen studies involving 3240 patients were analyzed. The pooled sensitivity and specificity of B-mode ultrasound for detecting S1 were 0.70 (95% confidence interval [CI], 0.63-0.77) and 0.86 (95% CI 0.82-0.89), respectively. The pooled PLR, NLR, and DOR were 4.90 (95% CI 3.69-6.51), 0.35 (95% CI 0.27- 0.44), and 14.1 (95% CI 8.7-23.0), respectively. The diagnostic accuracy was better in patients with attenuation coefficients (area under the curve [AUC], 0.89; sensitivity, 0.75; specificity, 0.86) than in those with conventional B-mode findings (AUC, 0.80; sensitivity, 0.59; specificity, 0.83). In particular, the diagnostic value was better when the attenuation coefficient guided by B-mode ultrasound was utilized. To screen patients with steatosis of ≥ 5%, attenuation coefficient should be used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesFatty LiverAdultBiopsyHumansLiverROC CurveUltrasonography

Stichwörter der Autor:innen

Attenuation coefficientB-mode ultrasoundFatty liverSteatosis

Autor:innen und Institutionen

  • Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Shitsukawa, Tōon, Ehime, 791-0295, Japan. masashih@m.ehime-u.ac.jp.
  • Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Shitsukawa, Tōon, Ehime, 791-0295, Japan.
  • Department of Gastroenterology and Metabology, National Hospital Organization Ehime Medical Center, Tōon, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Hirooka, M., Koizumi, Y., Sunago, K., Nakamura, Y., Hirooka, K., Watanabe, T., Yoshida, O., Tokumoto, Y., Abe, M., & Hiasa, Y. (2022). Efficacy of B-mode ultrasound-based attenuation for the diagnosis of hepatic steatosis: a systematic review/meta-analysis. Journal of Medical Ultrasonics, 49(2), 199-210. https://doi.org/10.1007/s10396-022-01196-5

Vancouver

Hirooka M, Koizumi Y, Sunago K, Nakamura Y, Hirooka K, Watanabe T, et al. Efficacy of B-mode ultrasound-based attenuation for the diagnosis of hepatic steatosis: a systematic review/meta-analysis. Journal of Medical Ultrasonics. 2022;49(2):199-210. doi:10.1007/s10396-022-01196-5

BibTeX
@article{Hirooka2022,
  author = {Hirooka, Masashi and Koizumi, Yohei and Sunago, Kotarou and Nakamura, Yoshiko and Hirooka, Kana and Watanabe, Takao and Yoshida, Osamu and Tokumoto, Yoshio and Abe, Masanori and Hiasa, Yoichi},
  title = {Efficacy of B-mode ultrasound-based attenuation for the diagnosis of hepatic steatosis: a systematic review/meta-analysis},
  journal = {Journal of Medical Ultrasonics},
  year = {2022},
  volume = {49},
  number = {2},
  pages = {199--210},
  doi = {10.1007/s10396-022-01196-5}
}
Kostenlos starten →