EUVIMEDEUVIMED entdecken
Übersichtsarbeit

How to standardize measurement of global longitudinal strain

Tomoko Negishi, Kazuaki Negishi

Journal of Medical Ultrasonics · 2022-01 · 49 (1) · 45-52

DOI: 10.1007/s10396-021-01160-9 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Medical Ultrasonics, online erschienen am 17.11.2021. Verfasst von Tomoko Negishi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine and Health, Charles Perkins Centre Nepean, Sydney Medical School Nepean, Nepean Hospital, The University of Sydney, Level 5 South…. Hauptthemen laut MEDLINE: Echocardiography, Ventricular Dysfunction, Left. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Heart Foundation of Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Global longitudinal strain (GLS) is a robust and sensitive marker of left-ventricular systolic function, reflecting longitudinal shortening of the ventricle. A growing body of evidence indicates its superiority in identifying subclinical, early alterations in cardiac function compared to traditional markers, such as ejection fraction. Therefore, there is a growing demand to assess GLS in clinical settings, but limited availability on how to obtain GLS accurately and appropriately in the current literature. This review summarizes key aspects of GLS measurement, including image acquisition, post-processing, and training/experience needed to facilitate the clinical implication with standardization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EchocardiographyVentricular Dysfunction, LeftHeart VentriclesHumansReproducibility of ResultsStroke VolumeVentricular Function, Left

Stichwörter der Autor:innen

ExperienceGlobal longitudinal strain (GLS)ReproducibilityStandardizationVendor difference

Autor:innen und Institutionen

  • Faculty of Medicine and Health, Charles Perkins Centre Nepean, Sydney Medical School Nepean, Nepean Hospital, The University of Sydney, Level 5 South Block, Kingswood, NSW, 2747, Australia.
  • Nepean Hospital, Kingswood, NSW, Australia.
  • Menzies Research Institute, University of Tasmania, Hobart, Australia.
  • Faculty of Medicine and Health, Charles Perkins Centre Nepean, Sydney Medical School Nepean, Nepean Hospital, The University of Sydney, Level 5 South Block, Kingswood, NSW, 2747, Australia. kazuaki.negishi@sydney.edu.au.
  • Nepean Hospital, Kingswood, NSW, Australia. kazuaki.negishi@sydney.edu.au.
  • Menzies Research Institute, University of Tasmania, Hobart, Australia. kazuaki.negishi@sydney.edu.au.

Förderung

  • National Heart Foundation of Australia

Zitieren

APA

Negishi, T., & Negishi, K. (2022). How to standardize measurement of global longitudinal strain. Journal of Medical Ultrasonics, 49(1), 45-52. https://doi.org/10.1007/s10396-021-01160-9

Vancouver

Negishi T, Negishi K. How to standardize measurement of global longitudinal strain. Journal of Medical Ultrasonics. 2022;49(1):45-52. doi:10.1007/s10396-021-01160-9

BibTeX
@article{Negishi2022,
  author = {Negishi, Tomoko and Negishi, Kazuaki},
  title = {How to standardize measurement of global longitudinal strain},
  journal = {Journal of Medical Ultrasonics},
  year = {2022},
  volume = {49},
  number = {1},
  pages = {45--52},
  doi = {10.1007/s10396-021-01160-9}
}
Kostenlos starten →