Manometric esophagogastric junction barrier metrics as predictors of gastroesophageal reflux
Esophagus · 2024
DOI: 10.1007/s10388-024-01057-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Esophagus, 2024. Verfasst von Shaili Babbar und 3 weiteren Autor:innen. Beteiligte Einrichtung: New York University Grossman School of Medicine, NYU Langone Health, 550 First Avenue, New York, NY, 10016, USA. Shaili.babbar@nyulangone.org. Hauptthemen laut MEDLINE: Gastroesophageal Reflux, Esophagogastric Junction, Manometry, Esophageal pH Monitoring. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: High-resolution manometry (HRM) tools, like esophagogastric junction contractile integral (EGJ-CI), assess EGJ barrier function. GOALS: This study aimed to evaluate the relationships between manometric EGJ metrics with esophageal acid exposure. STUDY: We conducted a retrospective review of 284 patients who underwent HRM and ambulatory reflux testing between 11/2017-1/2020. EGJ-CI and total-EGJ-CI were manually calculated. Pathologic acid exposure was defined as pH < 4 with esophageal acid exposure time (EAET) exceeding 6.0%. Pearson's correlation, univariable and multivariable regression models were utilized to assess the relationships between pathologic acid exposure and EGJ parameters. Sensitivity and specificity thresholds for EGJ-CI and total EGJ-CI were optimized with ROC analyses. RESULTS: On univariable analysis, patients with pathologic acid exposure had increased odds of having lower mean basal LES pressures, EGJ-CI, and total EGJ-CI than patients without pathologic acid exposure. On multivariable analysis, age, EGJ-CI and mean DCI were significant predictors of pathologic acid exposure. There were significant, though weak, correlations between EAET and EGJ-CI and total EGJ-CI (r = - 0.18, - 0.19, p < 0.01, respectively). An EGJ-CI cutoff of 44.16 as a predictor for pathologic acid exposure had a sensitivity of 46% and specificity of 42% (AUC 0.60). Total EGJ-CI cutoff of 11,461.3 for pathologic acid exposure had a sensitivity of 44% and a specificity of 43% (AUC 0.62). CONCLUSION: EGJ-CI can independently predict pathologic acid exposure. However, the poor correlation between EGJ-CI and acid exposure, as well as the low sensitivity and specificity of calculated thresholds, indicate that mechanisms other than EGJ barrier function may impact acid exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- New York University Grossman School of Medicine, NYU Langone Health, 550 First Avenue, New York, NY, 10016, USA. Shaili.babbar@nyulangone.org.
- Division of Gastroenterology & Hepatology, Department of Medicine, Center for Esophageal Health, NYU Langone Health, New York, NY, USA.
ORCID-Profile: Shaili Babbar
Zitieren
APA
Babbar, S., Omara, M., Khan, A., & Knotts, R. (2024). Manometric esophagogastric junction barrier metrics as predictors of gastroesophageal reflux. Esophagus. https://doi.org/10.1007/s10388-024-01057-9
Vancouver
Babbar S, Omara M, Khan A, Knotts R. Manometric esophagogastric junction barrier metrics as predictors of gastroesophageal reflux. Esophagus. 2024. doi:10.1007/s10388-024-01057-9
BibTeX
@article{Babbar2024,
author = {Babbar, Shaili and Omara, Matthew and Khan, Abraham and Knotts, Rita},
title = {Manometric esophagogastric junction barrier metrics as predictors of gastroesophageal reflux},
journal = {Esophagus},
year = {2024},
doi = {10.1007/s10388-024-01057-9}
}
EUVIMED