Clinical performance of the multiplex solid-phase “Direct Strip PCR” for infectious uveitis: a multicenter diagnostic accuracy study
Japanese Journal of Ophthalmology · 2026-07 · 70 (4) · 966-982
DOI: 10.1007/s10384-026-01343-2 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Japanese Journal of Ophthalmology, online erschienen am 02.04.2026. Verfasst von Satoko Nakano und 59 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Oita University Faculty of Medicine, 1-1 Idaigaoka, Hasama-cho, Yufu, Oita, 879-5593, Japan. sanakano@oita-u.ac.jp. Hauptthemen laut MEDLINE: Aqueous Humor, DNA, Viral, Eye Infections, Multiplex Polymerase Chain Reaction. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Agency for Medical Research and Development, Shimadzu, Oita University.
Abstract (Originalsprache)
Purpose
To evaluate the clinical performance of “Direct Strip PCR,” a multiplex solid-phase real-time polymerase chain reaction (PCR) kit, for diagnosing infectious uveitis. Study design Multicenter, prospective, diagnostic accuracy study Methods We analyzed 475 ocular-fluid samples (336 aqueous humor and 139 vitreous fluid) from 29 sites in Japan. Direct Strip PCR, an IVD-grade multiplex real-time PCR kit targeting HSV-1, HSV-2, VZV, EBV, CMV, HHV-6, HTLV-1, Toxoplasma gondii , and Treponema pallidum requiring no DNA extraction and incorporating internal controls, was compared with quantitative PCR (qPCR) for concordance and DNA copy-number correlation.
Results
All 9 of the target pathogens were detected. Direct Strip PCR showed excellent agreement with qPCR, with percent positive agreement (PPA), percent negative agreement (PNA), and percent overall agreement (POA) in aqueous humor of 98.0%, 99.2%, and 98.5%, respectively, and in vitreous fluid of 95.7%, 97.1%, and 96.4%, respectively, indicating high concordance for positive and negative results. All the values exceeded predefined 90% thresholds agreed upon with the Pharmaceuticals and Medical Devices Agency, meeting the required performance criteria. Discordant results were infrequent (10/4275 targets) and involved low-copy samples near the detection limit. The DNA copy numbers correlated strongly between the methods (r = 0.948–0.996). No adverse events were reported.
Conclusion
Direct Strip PCR demonstrated high concordance with qPCR, reliably detected major pathogens of infectious uveitis, and yielded quantitative results that correlated with the qPCR results, supporting disease monitoring. Its solid-phase, extraction-free, and per-run calibration-free format provides a practical basis for regulatory submissions and global dissemination of multiplex PCR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Oita University Faculty of Medicine, 1-1 Idaigaoka, Hasama-cho, Yufu, Oita, 879-5593, Japan. sanakano@oita-u.ac.jp.
- Sugita Eye Clinic, Miyazaki, Japan.
- Department of Ophthalmology, Kobe City Eye Hospital, Kobe, Japan.
- Miyata Eye Hospital Tokyo Clinic, Tokyo, Japan.
- Department of Ophthalmology, Oita University Faculty of Medicine, 1-1 Idaigaoka, Hasama-cho, Yufu, Oita, 879-5593, Japan.
- Department of Ophthalmology, Gunma University Graduate School of Medicine, Maebashi, Japan.
Förderung
- Japan Agency for Medical Research and Development
- Shimadzu
- Oita University
Zitieren
APA
Nakano, S., Sugita, S., Takase, H., Tomaru, Y., Todokoro, D., Hasegawa, Y., Ikeda, Y., Mawatari, G., Sotozono, C., Nagata, K., Araki-Sasaki, K., Nakagawa, S., Kiuchi, Y., Mitoma, K., Yawata, N., Hariya, T., Uchio, E., Tsukahara-Kawamura, T., Inoue, H., …, & Kubota, T. (2026). Clinical performance of the multiplex solid-phase “Direct Strip PCR” for infectious uveitis: a multicenter diagnostic accuracy study. Japanese Journal of Ophthalmology, 70(4), 966-982. https://doi.org/10.1007/s10384-026-01343-2
Vancouver
Nakano S, Sugita S, Takase H, Tomaru Y, Todokoro D, Hasegawa Y, et al. Clinical performance of the multiplex solid-phase “Direct Strip PCR” for infectious uveitis: a multicenter diagnostic accuracy study. Japanese Journal of Ophthalmology. 2026;70(4):966-982. doi:10.1007/s10384-026-01343-2
BibTeX
@article{Nakano2026,
author = {Nakano, Satoko and Sugita, Sunao and Takase, Hiroshi and Tomaru, Yasuhiro and Todokoro, Daisuke and Hasegawa, Yumi and Ikeda, Yasuhiro and Mawatari, Go and Sotozono, Chie and Nagata, Kenji and Araki-Sasaki, Kaoru and Nakagawa, Suguru and Kiuchi, Yoshiaki and Mitoma, Kaori and Yawata, Nobuyo and Hariya, Takehiro and Uchio, Eiichi and Tsukahara-Kawamura, Tomoko and Inoue, Hidenori and Toriyama, Koji and Kusuhara, Sentaro and Matsumiya, Wataru and Ohguro, Nobuyuki and Mashimo, Hisashi and Fukuda, Ken and Ishida, Waka and Egawa, Mariko and Nakai, Kei and Morioka, Masakazu and Hayashi, Atsushi and Nakamura, Tomoko and Usui, Yoshihiko and Goto, Hiroshi and Nejima, Ryohei and Miyata, Kazunori and Namba, Kenichi and Hase, Keitaro and Okada, Annabelle A and Keino, Hiroshi and Mizuki, Nobuhisa and Takeuchi, Masaki and Miyazaki, Dai and Kiyosaki, Kunihiro and Kinouchi, Reiko and Yanai, Ryoji and Uchi, Sho-Hei and Yashiro, Shigeko and Tanaka, Rie and Tsutsui, Aika and Suzuki, Takashi and Umeki, Yukiko and Yahiro, Takaaki and Sonezaki, Akane and Matsumoto, Takashi and Ohyama, Tetsuji and Kuranari, Masae and Uemura, Naoto and Hori, Yuichi and Takeda, Atsunobu and Kubota, Toshiaki},
title = {Clinical performance of the multiplex solid-phase “Direct Strip PCR” for infectious uveitis: a multicenter diagnostic accuracy study},
journal = {Japanese Journal of Ophthalmology},
year = {2026},
volume = {70},
number = {4},
pages = {966--982},
doi = {10.1007/s10384-026-01343-2}
}