EUVIMEDEUVIMED entdecken
Crossref

Development of a reliability criterion for the binocular Esterman visual field test

Kazunori Hirasawa, Akari Nagayama-Ito, Chiho Maruta-Akaishizawa, Nobuyuki Shoji

Japanese Journal of Ophthalmology · 2025

DOI: 10.1007/s10384-025-01238-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Ophthalmology, 2025. Verfasst von Kazunori Hirasawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan. hirasawa@kita…. Hauptthemen laut MEDLINE: Visual Fields, Visual Field Tests, Vision, Binocular, Glaucoma. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Kitasato University School of Medicine, Alcon Japan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the repeatability of the binocular Esterman visual field (bEVF) test and develop a corresponding reliability criterion based on repeatability-associated factors. STUDY DESIGN: Prospective cross-sectional study. METHODS: Ninety-five glaucoma patients underwent two bEVF tests on the same day using a Humphrey field analyzer. The repeatability of the bEVF was assessed by the agreement rate for seen and unseen points over all test points between the first and second tests. Factors associated with the repeatability were analyzed with multivariate linear regression analysis. Receiver operating characteristic (ROC) curve analysis was performed for those associated factors to identify the reliability criterion. RESULTS: The mean agreement rate was 88.9% (95% confidence interval [CI]: 73.9%, 99.2%). A total of 44 patients (46.3%), 75 patients (78.9%), and 88 patients (92.6%) had agreement rates of more than 90%, 85%, and 80%, respectively. The false positive (FP) response rate of the bEVF test was negatively associated with the agreement rate (p 7.1% (sensitivity = 71.0% and specificity = 88.0%), while the cutoff value based on a fixed 95% specificity was >12.1% (sensitivity = 28.6%). CONCLUSION: An approximately 90% agreement rate existed for the bEVF test when applied to glaucoma patients. The FP response rate was associated with the repeatability of the bEVF test, and 8% or at least 13% may serve as a useful reference to ensure an agreement rate of 80% or higher.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual FieldsVisual Field TestsVision, BinocularGlaucomaHumansCross-Sectional StudiesMaleFemaleProspective StudiesReproducibility of ResultsMiddle AgedROC CurveAgedIntraocular PressureAdult

Stichwörter der Autor:innen

Binocular visual fieldEsterman testVisual field

Autor:innen und Institutionen

  • Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan. hirasawa@kitasato-u.ac.jp.
  • Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan.

Förderung

  • Kitasato University School of Medicine
  • Alcon Japan

Zitieren

APA

Hirasawa, K., Nagayama-Ito, A., Maruta-Akaishizawa, C., & Shoji, N. (2025). Development of a reliability criterion for the binocular Esterman visual field test. Japanese Journal of Ophthalmology. https://doi.org/10.1007/s10384-025-01238-8

Vancouver

Hirasawa K, Nagayama-Ito A, Maruta-Akaishizawa C, Shoji N. Development of a reliability criterion for the binocular Esterman visual field test. Japanese Journal of Ophthalmology. 2025. doi:10.1007/s10384-025-01238-8

BibTeX
@article{Hirasawa2025,
  author = {Hirasawa, Kazunori and Nagayama-Ito, Akari and Maruta-Akaishizawa, Chiho and Shoji, Nobuyuki},
  title = {Development of a reliability criterion for the binocular Esterman visual field test},
  journal = {Japanese Journal of Ophthalmology},
  year = {2025},
  doi = {10.1007/s10384-025-01238-8}
}
Kostenlos starten →