EUVIMEDEUVIMED entdecken
Crossref

In vivo T1 and T2 relaxation times of the rodent brain at 5.0 T: cross-species quantification on a clinical MRI platform

Xinxin Zhao, Xin Xu, Wen Wang, Jiahui Cheng, Shiteng Suo, Shaofeng Duan, Bo Li, Yan Zhou

Magnetic Resonance Materials in Physics, Biology and Medicine · 11.11.2026

DOI: 10.1007/s10334-026-01437-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 11.11.2026. Verfasst von Xinxin Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Renji Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No. 160 Pujian Rd.,Pudong New District, Shang…. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Eastern Talent Plan Leading Project, Shanghai Science and Technology Committee Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECT: To assess the technical reproducibility of quantitative T1 and T2 mapping and characterize regional brain relaxation values in healthy rats and mice using a clinical 5.0-T MRI system with dedicated rodent coils. MATERIALS AND METHODS: Twenty Sprague-Dawley rats and 20 C57BL/6 mice, with equal numbers of females and males, underwent baseline and next-day MRI. T1 and T2 were measured using B1-corrected variable flip angle mapping and a CPMG-based multislice multiecho sequence, respectively. Six brain regions were measured independently by two blinded readers. Technical performance was assessed using repeatedly scanned single-compartment and nine-concentration CuSO4 · 5H2O phantoms. Scan-rescan and interobserver reproducibility were evaluated using intraclass correlation coefficients (ICCs) and coefficients of variation (CVs). RESULTS: Phantom R1 and R2 demonstrated strong linear relationships with CuSO4 · 5H2O concentration (R2 = 0.9763 and 0.9583, respectively; both P < 0.001). Regional scan-rescan ICCs were 0.89-0.94 for T1 and 0.88-0.94 for T2, with corresponding CVs of 2.4%-6.9% and 2.6%-5.5%, respectively. Interobserver reproducibility was excellent. Both species showed the longest relaxation times in cerebrospinal fluid and the shortest in the corpus callosum. Mice had significantly longer T1 values than rats in all evaluated regions (all P < 0.001), whereas a significant interspecies difference in T2 was observed only in cerebrospinal fluid (P < 0.001). DISCUSSION: Clinical 5.0-T MRI provides reproducible, platform- and protocol-specific regional T1 and T2 measurements in healthy adult rats and mice. These reference measurements support the application of clinical 5.0-T systems in preclinical quantitative and translational MRI research.

Schlagwörter

Stichwörter der Autor:innen

5.0-T MRIRodent brainT1 mappingT2 mapping

Autor:innen und Institutionen

  • Department of Radiology, Renji Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No. 160 Pujian Rd.,Pudong New District, Shanghai, 200127, China.
  • Collaborative Innovation Department, United Imaging Healthcare, No. 2258 Chengbei Rd.,Jiading District, Shanghai, 201807, China.
  • Department of Radiology, Renji Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No. 160 Pujian Rd.,Pudong New District, Shanghai, 200127, China. clare1475@hotmail.com.
  • Department of Radiology & Faculty of Medical Imaging Technology, Renji Hospital, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, No. 1Banxia Rd.,Pudong New District, Shanghai,…

Förderung

  • National Natural Science Foundation of China
  • Shanghai Eastern Talent Plan Leading Project
  • Shanghai Science and Technology Committee Project
  • China National Key R&D Program
  • Renji Hospital Crosswise Project
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Zhao, X., Xu, X., Wang, W., Cheng, J., Suo, S., Duan, S., Li, B., & Zhou, Y. (2026). In vivo T1 and T2 relaxation times of the rodent brain at 5.0 T: cross-species quantification on a clinical MRI platform. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01437-5

Vancouver

Zhao X, Xu X, Wang W, Cheng J, Suo S, Duan S, et al. In vivo T1 and T2 relaxation times of the rodent brain at 5.0 T: cross-species quantification on a clinical MRI platform. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01437-5

BibTeX
@article{Zhao2026,
  author = {Zhao, Xinxin and Xu, Xin and Wang, Wen and Cheng, Jiahui and Suo, Shiteng and Duan, Shaofeng and Li, Bo and Zhou, Yan},
  title = {In vivo T1 and T2 relaxation times of the rodent brain at 5.0 T: cross-species quantification on a clinical MRI platform},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  doi = {10.1007/s10334-026-01437-5}
}
Kostenlos starten →