Thoracic outlet syndrome (TOS) results from compression of neurovascular structures. Dynamic MRI may enhance diagnostic accuracy; however, conventional rigid coils are suboptimal for imaging during functional maneuvers. This study compared a custom-built flexible modular coil (ModFlex) with a conventional torso coil, focusing on the interscalene (ISS) and costoclavicular spaces (CCS). Nine healthy volunteers participated in 3 T TOS MRI using both coils. The signal-to-noise ratio (SNR) was calculated in two regions of interest (ISS and CCS). Additionally, g-factors were evaluated for simulated GRAPPA parallel imaging factors from 3 to 6. Two clinicians visually rated T1-weighted sagittal images to assess ModFlex coil performance. Quantitative data were compared using the Wilcoxon signed-rank and the ranks with the sign test. The ModFlex demonstrated a significantly higher SNR in the CCS (+ 39%, p = 0.004), a trend toward higher SNR in the ISS (+ 17%, p = 0.098), and significantly lower g-factors (i.e., higher parallel imaging performance) across all acceleration levels (p < 0.008). The clinicians' evaluation was generally consistent with quantitative findings, although not conclusive. GRAPPA acceleration provided better image quality than SMS (p = 0.008). Overall, modular flexible coils support faster, higher-quality dynamic TOS MRI protocols, potentially improving diagnostic reliability, and patient comfort.
Autor:innen und Institutionen
- SIEMENS Healthcare SAS, Courbevoie, France.
- IADI, Université de Lorraine, U1254 INSERM, 54000, Nancy, France.
- Département d'Anatomie, Université de Lorraine, 54000, Nancy, France.
- Service de Médecine Physique et de Réadaptation, CHRU de Nancy, 54000, Nancy, France.
- Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 54000, Nancy, France.
- CIC-IT 1433, INSERM, CHRU de Nancy, 54000, Nancy, France.
Zitieren
APA
Truong, C., Assabah, B., Teixeira, P., Kirsch, A., Vuissoz, P. A., Gillet, R., Laistler, E., Felblinger, J., Nohava, L., & Isaieva, K. (2026). Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01410-2
Vancouver
Truong C, Assabah B, Teixeira P, Kirsch A, Vuissoz PA, Gillet R, et al. Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01410-2
BibTeX
@article{Truong2026,
author = {Truong, Catherine and Assabah, Bouchra and Teixeira, Pedro and Kirsch, Audrey and Vuissoz, Pierre-André and Gillet, Romain and Laistler, Elmar and Felblinger, Jacques and Nohava, Lena and Isaieva, Karyna},
title = {Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2026},
doi = {10.1007/s10334-026-01410-2}
}
EUVIMED