EUVIMEDEUVIMED entdecken
Crossref

Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T

Catherine Truong, Bouchra Assabah, Pedro Teixeira, Audrey Kirsch, Pierre-André Vuissoz, Romain Gillet, Elmar Laistler, Jacques Felblinger, Lena Nohava, Karyna Isaieva

Magnetic Resonance Materials in Physics, Biology and Medicine · 21.08.2026

DOI: 10.1007/s10334-026-01410-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 21.08.2026. Verfasst von Catherine Truong und 9 weiteren Autor:innen. Beteiligte Einrichtung: SIEMENS Healthcare SAS, Courbevoie, France. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thoracic outlet syndrome (TOS) results from compression of neurovascular structures. Dynamic MRI may enhance diagnostic accuracy; however, conventional rigid coils are suboptimal for imaging during functional maneuvers. This study compared a custom-built flexible modular coil (ModFlex) with a conventional torso coil, focusing on the interscalene (ISS) and costoclavicular spaces (CCS). Nine healthy volunteers participated in 3 T TOS MRI using both coils. The signal-to-noise ratio (SNR) was calculated in two regions of interest (ISS and CCS). Additionally, g-factors were evaluated for simulated GRAPPA parallel imaging factors from 3 to 6. Two clinicians visually rated T1-weighted sagittal images to assess ModFlex coil performance. Quantitative data were compared using the Wilcoxon signed-rank and the ranks with the sign test. The ModFlex demonstrated a significantly higher SNR in the CCS (+ 39%, p = 0.004), a trend toward higher SNR in the ISS (+ 17%, p = 0.098), and significantly lower g-factors (i.e., higher parallel imaging performance) across all acceleration levels (p < 0.008). The clinicians' evaluation was generally consistent with quantitative findings, although not conclusive. GRAPPA acceleration provided better image quality than SMS (p = 0.008). Overall, modular flexible coils support faster, higher-quality dynamic TOS MRI protocols, potentially improving diagnostic reliability, and patient comfort.

Autor:innen und Institutionen

  • SIEMENS Healthcare SAS, Courbevoie, France.
  • IADI, Université de Lorraine, U1254 INSERM, 54000, Nancy, France.
  • Département d'Anatomie, Université de Lorraine, 54000, Nancy, France.
  • Service de Médecine Physique et de Réadaptation, CHRU de Nancy, 54000, Nancy, France.
  • Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 54000, Nancy, France.
  • CIC-IT 1433, INSERM, CHRU de Nancy, 54000, Nancy, France.

Zitieren

APA

Truong, C., Assabah, B., Teixeira, P., Kirsch, A., Vuissoz, P. A., Gillet, R., Laistler, E., Felblinger, J., Nohava, L., & Isaieva, K. (2026). Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01410-2

Vancouver

Truong C, Assabah B, Teixeira P, Kirsch A, Vuissoz PA, Gillet R, et al. Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01410-2

BibTeX
@article{Truong2026,
  author = {Truong, Catherine and Assabah, Bouchra and Teixeira, Pedro and Kirsch, Audrey and Vuissoz, Pierre-André and Gillet, Romain and Laistler, Elmar and Felblinger, Jacques and Nohava, Lena and Isaieva, Karyna},
  title = {Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  doi = {10.1007/s10334-026-01410-2}
}
Kostenlos starten →