EUVIMEDEUVIMED entdecken
Crossref

Influence of gadolinium-based contrast agent (GBCA) on the diffusion weightings of breast lesions: an intra-patient analysis

Kay J J van der Hoogt, Robert-Jan Schipper, Leon C Ter Beek, Ronni Wessels, Hedda J van der Hulst, Arjan Te Boekhorst, Regina G H Beets-Tan, Ritse M Mann

Magnetic Resonance Materials in Physics, Biology and Medicine · 29.06.2026

DOI: 10.1007/s10334-026-01381-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 29.06.2026. Verfasst von Kay J J van der Hoogt und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. k.…. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the influence of gadolinium-based contrast agent (GBCA) administration on breast lesions’ signal intensities on diffusion-weighted images and its derived ADC maps acquired 2 min after GBCA administration. Materials and methods An intra-patient analysis was performed. 110 lesions > 5 mm in 93 patients, visible on screening and pre-operative MRI scans at 1.5 T and 3.0 T, were included. Pre-contrast and post-contrast DWI were acquired with single-shot spin-echo echo-planar imaging (SSh-SE-EPI) with b0, b50, b150, and b800 diffusion weightings. 2D regions of interest were drawn. Each b value was separately analyzed regarding signal intensities on DWI. Furthermore, ADC values were compared based on the pairs b0–b800 and b150–b800. The comparison between pre- and post-contrast DWIs was investigated within and between different groups (overall, malignant/benign, and at 1.5/3.0 T). The Wilcoxon-signed rank test and independent Student T test were used when appropriate. P < 0.01 was considered as statistically significant.

Results

Overall, and for malignant and benign lesions separately, a significant change after contrast administration in signal intensity was observed at each specific b value, irrespective of the use of 1.5 T or 3.0 T. The effect of contrast administration was overall notably different when comparing b0 (+ 9.4%) vs. b800 (+ 11.8%), but this was not observed between b150 (11.4%) and b800 (11.8%) ( P = 0.10). In malignant lesions, specifically, all b value pairs, except b0–b50, showed significant differences in GBCA effects. This translates into a pre–post-contrast difference of the ADC value of 3.2% ( P = 0.02) when based on b0–b800 and 0.9% ( P = 0.11) when using b150–800.

Conclusions

There is a limited, but significant effect of contrast administration on DW signal intensities measured 2 min after contrast administration. This effect is not the same for each b value. Signal change is stronger for high than for low b values, which leads to a larger change in measured ADC values after contrast administration when b0 and b50 are incorporated in the calculation. As a consequence, ADC calculations obtained from b150–b800 seem to be more robust than those obtained from b0–b800.

Schlagwörter

Stichwörter der Autor:innen

Breast cancerDWIGBCA

Autor:innen und Institutionen

  • Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. k.vd.hoogt@nki.nl.
  • GROW School of Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht, The Netherlands. k.vd.hoogt@nki.nl.
  • Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
  • Department of Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
  • Department of Medical Physics, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • GROW School of Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht, The Netherlands.

Zitieren

APA

van der Hoogt, K. J. J., Schipper, R. J., Ter Beek, L. C., Wessels, R., van der Hulst, H. J., Boekhorst, A. T., Beets-Tan, R. G. H., & Mann, R. M. (2026). Influence of gadolinium-based contrast agent (GBCA) on the diffusion weightings of breast lesions: an intra-patient analysis. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01381-4

Vancouver

van der Hoogt KJJ, Schipper RJ, Ter Beek LC, Wessels R, van der Hulst HJ, Boekhorst AT, et al. Influence of gadolinium-based contrast agent (GBCA) on the diffusion weightings of breast lesions: an intra-patient analysis. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01381-4

BibTeX
@article{vanderHoogt2026,
  author = {van der Hoogt, Kay J J and Schipper, Robert-Jan and Ter Beek, Leon C and Wessels, Ronni and van der Hulst, Hedda J and Boekhorst, Arjan Te and Beets-Tan, Regina G H and Mann, Ritse M},
  title = {Influence of gadolinium-based contrast agent (GBCA) on the diffusion weightings of breast lesions: an intra-patient analysis},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  doi = {10.1007/s10334-026-01381-4}
}
Kostenlos starten →