Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 26.05.2026. Verfasst von Quintin van Lohuizen und 6 weiteren Autor:innen. Beteiligte Einrichtung: University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, the Netherlands. q.y.van.lohuizen@umcg.nl. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers, Health~Holland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Although undersampling combined with deep learning (DL)-based reconstruction shortens MRI acquisition, it increases the chance of inaccuracies, highlighting the need for quantifiable uncertainty measures. Two inference-time perturbation strategies, echo-train dropout (ET-Drop) and Gaussian noise Monte Carlo sampling (GN-MC), were compared in terms of the correlation between their variance-based uncertainty maps and absolute reconstruction error in DL-accelerated T2w prostate MRI.

Methods

This retrospective multi-center study used a publicly available dataset with 312 k-spaces from NYU for training and a dataset with 120 k-spaces from University Medical Center Groningen for external validation. Fully sampled 3 T data were retrospectively undersampled to acceleration factors R = 3 and R = 6 and reconstructed by a vSHARP model. Per slice, five GN-MC perturbations were reconstructed by adding complex noise at 2.5σ, and five ET-Drop perturbations, created by omitting non-central echo trains. Voxel-wise aleatoric uncertainty was defined as the variance (σ 2 ) across these reconstructions and correlated with absolute reconstruction error over whole slices and within the prostate.

Results

Both uncertainties yielded moderate slice-level correlations with absolute error. At R = 3, ET-Drop slightly outperformed GN-MC (median ρ = 0.39 vs 0.35; p < 0.001). At R = 6, the ranking reversed (0.44 vs 0.40; p < 0.001). Correlations within the prostate fell to 0.10–0.15. ET-Drop variance maps were dominated by coil sensitivities.

Conclusion

Both perturbation strategies yield variance-based uncertainty maps that correlate moderately with voxel-wise error. More importantly, they consistently highlighted acquisition-related fragility, supporting the role of uncertainty mapping as a useful quality-control tool in prostate MRI.

Schlagwörter

Stichwörter der Autor:innen

Computer-assistedDeep learningImage reconstructionMagnetic resonance imagingMonte Carlo methodProstateUncertainty quantification

Autor:innen und Institutionen

  • University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, the Netherlands. q.y.van.lohuizen@umcg.nl.
  • , Piet Fransenlaan 127, 9713WN, Groningen, the Netherlands. q.y.van.lohuizen@umcg.nl.
  • University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, the Netherlands.
  • Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, the Netherlands.
  • University of Twente, Drienerlolaan 5, 7522 NB, Enschede, the Netherlands.
  • Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, the Netherlands.

Förderung

  • Siemens Healthineers
  • Health~Holland

Zitieren

APA

van Lohuizen, Q., Fransen, S. J., Huisman, H., Wolterink, J. M., Kwee, T. C., Yakar, D., & Simonis, F. F. J. (2026). Aleatoric uncertainty in accelerated prostate MRI reconstruction: echo-train dropout versus Gaussian noise Monte Carlo sampling. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01369-0

Vancouver

van Lohuizen Q, Fransen SJ, Huisman H, Wolterink JM, Kwee TC, Yakar D, et al. Aleatoric uncertainty in accelerated prostate MRI reconstruction: echo-train dropout versus Gaussian noise Monte Carlo sampling. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01369-0

BibTeX
@article{vanLohuizen2026,
  author = {van Lohuizen, Quintin and Fransen, Stefan J and Huisman, Henkjan and Wolterink, Jelmer M and Kwee, Thomas C and Yakar, Derya and Simonis, Frank F J},
  title = {Aleatoric uncertainty in accelerated prostate MRI reconstruction: echo-train dropout versus Gaussian noise Monte Carlo sampling},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  doi = {10.1007/s10334-026-01369-0}
}
Kostenlos starten →