EUVIMEDEUVIMED entdecken
Crossref

Investigating the potential of segmented echo-planar imaging-based susceptibility-weighted imaging for glioma grading

Satyajit Maurya, Rakesh Kumar Gupta, Anup Singh

Magnetic Resonance Materials in Physics, Biology and Medicine · 27.03.2026

DOI: 10.1007/s10334-026-01347-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 27.03.2026. Verfasst von Satyajit Maurya und 2 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India. Die Arbeit nennt 37 Literaturangaben. Gefördert von: ICMR, SERB DST, Prime Minister’s Research Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Susceptibility-weighted imaging (SWI) has shown potential in glioma grading using features like intratumoral susceptibility signals (ITSS). Segmented echo-planar imaging-based SWI (SWI-EPI) sequence offers good spatial coverage and a high signal-to-noise ratio. OBJECTIVE: To evaluate segmented echo-planar imaging-based susceptibility-weighted imaging (SWI-EPI) for glioma grading utilizing ITSS volume (ITV) and a proposed new metric, normalized ITV (nITV), calculated as the ratio of ITV to total tumor volume, to improve grading accuracy. METHODS: ITSS were segmented from the SWI-EPI sequence. ITV was computed and normalized by whole tumor volume to derive nITV. Statistical analysis included Shapiro-Wilk, Mann-Whitney, Kruskal-Wallis, and receiver-operating-characteristic (ROC) curve analyses to assess the effectiveness of both the metrics in glioma grading. RESULTS: The proposed nITV metric significantly enhanced glioma grading accuracy. The area under the ROC curve (AUC) for nITV was consistently higher than for ITV when differentiating between grades 2 vs. 3 (0.886 vs. 0.818), 2 vs. 4 (0.969 vs. 0.939), and 3 vs. 4 (0.832 vs. 0.788). For differentiating low- vs. high-grade gliomas, nITV achieved an AUC of 0.95. Confusion matrices confirmed nITV led to fewer misclassifications. CONCLUSION: ITSS quantification from SWI-EPI is effective for tumor evaluation. The proposed nITV metric provides superior glioma grading efficiency compared to ITV.

Schlagwörter

Stichwörter der Autor:innen

Echo planar imagingGlioma gradingIntratumoral susceptibility signalMRISusceptibility-weighted imaging

Autor:innen und Institutionen

  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India.
  • Fortis Memorial Research Institute, Gurugram, India.
  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India. anupsm@iitd.ac.in.
  • Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi, India. anupsm@iitd.ac.in.
  • Yardi School of Artificial Intelligence (ScAI), Indian Institute of Technology Delhi, New Delhi, India. anupsm@iitd.ac.in.

Förderung

  • ICMR
  • SERB DST
  • Prime Minister’s Research Fellowship

Zitieren

APA

Maurya, S., Gupta, R. K., & Singh, A. (2026). Investigating the potential of segmented echo-planar imaging-based susceptibility-weighted imaging for glioma grading. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01347-6

Vancouver

Maurya S, Gupta RK, Singh A. Investigating the potential of segmented echo-planar imaging-based susceptibility-weighted imaging for glioma grading. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01347-6

BibTeX
@article{Maurya2026,
  author = {Maurya, Satyajit and Gupta, Rakesh Kumar and Singh, Anup},
  title = {Investigating the potential of segmented echo-planar imaging-based susceptibility-weighted imaging for glioma grading},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2026},
  doi = {10.1007/s10334-026-01347-6}
}
Kostenlos starten →