Assessing the cervical canal area in multiple sclerosis with spinal cord sagittal 2D T2-weighted sequences
Magnetic Resonance Materials in Physics, Biology and Medicine · 17.03.2026 · 39 (5) · 783-792
DOI: 10.1007/s10334-026-01344-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 17.03.2026. Verfasst von Neus Mongay-Ochoa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Centre d'Esclerosi Múltiple de Catalunya, (Cemcat), Vall d'Hebron Institut de Recerca, Vall d'Hebron Hospital Universitari, …. Hauptthemen laut MEDLINE: Multiple Sclerosis, Magnetic Resonance Imaging, Cervical Vertebrae, Cervical Cord. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: We explored the feasibility of our pipeline to make semi-automated estimations of the cervical canal area (CCaA), a proxy for spinal cord reserve in multiple sclerosis (MS), using conventional MRI sequences other than 3D T1-weighted images (T1WI), with which the pipeline was initially validated. MATERIALS AND METHODS: Fifty-three patients with MS underwent sagittal brain 3DT1WI and cervical 2DT1WI, T2WI, and short tau inversion recovery (STIR). Semi-automated CCaA estimations were obtained from reconstructed axial images at the C2/C3 and C3/C4 levels. Agreement with manual segmentations was evaluated using the Dice coefficient (DC). Intraclass correlation coefficients (ICC) assessed consistency across sequences, and Spearman correlation tested associations with Expanded Disability Status Scale (EDSS). RESULTS: After quality control, the final cohort comprised 36 patients with MS at the C2/C3 level and 43 at C3/C4. CCaA estimation failed on 2DT1WI. Agreement with manual masks was stronger for T2WI (DC = 0.92 [0.89-0.93]) and STIR (DC = 0.90 [0.88-0.92]). The equivalence of CCaA across sequences was higher at C3/C4 than at C2/C3: ICC T2WI-3DT1WI was 0.67 (0.38-0.82) and 0.63 (0.26-0.82), while ICC STIR-3DT1WI was 0.80 (0.64-0.89) and 0.52 (0.22-0.70), respectively. At C3/C4, T2WI CCaA and EDSS were significantly correlated (rho -0.34, p 0.023). DISCUSSION: CCaA can be reliably estimated from 2DT2WI and STIR images. T2WI-derived CCaA was significantly associated with disability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Centre d'Esclerosi Múltiple de Catalunya, (Cemcat), Vall d'Hebron Institut de Recerca, Vall d'Hebron Hospital Universitari, Barcelona, Spain.
- Department of Radiology (IDI), Section of Neuroradiology, Hospital Universitari Vall d'Hebron, Psg Vall Hebron 119-129, 08035, Barcelona, Spain. deborah.pareto.idi@gencat.cat.
- Department of Radiology (IDI), Section of Neuroradiology, Hospital Universitari Vall d'Hebron, Psg Vall Hebron 119-129, 08035, Barcelona, Spain.
Zitieren
APA
Mongay-Ochoa, N., Pareto, D., Ajdinaj, P., Alberich, M., Tintore, M., Montalban, X., Rovira, À., & Sastre-Garriga, J. (2026). Assessing the cervical canal area in multiple sclerosis with spinal cord sagittal 2D T2-weighted sequences. Magnetic Resonance Materials in Physics, Biology and Medicine, 39(5), 783-792. https://doi.org/10.1007/s10334-026-01344-9
Vancouver
Mongay-Ochoa N, Pareto D, Ajdinaj P, Alberich M, Tintore M, Montalban X, et al. Assessing the cervical canal area in multiple sclerosis with spinal cord sagittal 2D T2-weighted sequences. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026;39(5):783-792. doi:10.1007/s10334-026-01344-9
BibTeX
@article{MongayOchoa2026,
author = {Mongay-Ochoa, Neus and Pareto, Deborah and Ajdinaj, Paola and Alberich, Manel and Tintore, Mar and Montalban, Xavier and Rovira, Àlex and Sastre-Garriga, Jaume},
title = {Assessing the cervical canal area in multiple sclerosis with spinal cord sagittal 2D T2-weighted sequences},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2026},
volume = {39},
number = {5},
pages = {783--792},
doi = {10.1007/s10334-026-01344-9}
}
EUVIMED