Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography
Magnetic Resonance Materials in Physics, Biology and Medicine · 2025
DOI: 10.1007/s10334-025-01296-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Rashed Sobhan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK. rashed.sobhan@nottingham.ac.uk. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Pelvic Floor, Defecation, Defecography. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Nottingham University Hospitals NHS Trust.
Abstract (Originalsprache)
Objective
We tested the feasibility, data quality, and reliability of an upright magnetic resonance defaecating proctography (uMRDP) technique using an Open 0.5 T ASG MRI scanner. Materials and methods Eight healthy volunteers (2 males) performed seated defaecation on a purpose-built radio-frequency commode coil in an Open scanner. An optimised T2-weighted HASTE sequence captured dynamic changes during all three phases of the Kegel manoeuvre. Inter- and intra-rater variability was measured from the pelvic floor (PF) metrices (M-line, H-line, distances of landmarks) extracted by two radiologists.
Results
All relevant PF landmarks could be identified and metrices were extracted with acceptable inter- and intra-rater variability. Intra-rater variation was marginal, with relative absolute differences ranging from 5 to 21% and 3.2–44%. Inter-rater variability was reported using correlation and Bland-Altman plots. Correlation between raters was satisfactory, with r 2 > 0.93, and bias ranged from − 1.8 to 0.65 mm. Moreover, the limit of agreement in the Bland-Altman plot ranged from 5.8 to 20.4 mm, indicating satisfactory precision.
Discussion
The proposed uMRDP technique can be used as a feasible and reliable alternative to supine MRDP, without the necessity of gadolinium injection and bowel preparation. It can capture defaecation in a regular seated posture and can provide information complementary to standard-of-care fluoroscopic proctography for clinicians.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK. rashed.sobhan@nottingham.ac.uk.
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom. rashed.sobhan@nottingham.ac.uk.
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK.
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom.
- Department of Radiology, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Förderung
- Engineering and Physical Sciences Research Council
- Nottingham University Hospitals NHS Trust
Zitieren
APA
Sobhan, R., Glover, P. M., Gowland, P. A., Munyal, R., Mougin, O. E., & Clarke, C. G. D. (2025). Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01296-6
Vancouver
Sobhan R, Glover PM, Gowland PA, Munyal R, Mougin OE, Clarke CGD. Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01296-6
BibTeX
@article{Sobhan2025,
author = {Sobhan, Rashed and Glover, Paul M and Gowland, Penny A and Munyal, Rahul and Mougin, Olivier E and Clarke, Christopher G D},
title = {Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2025},
doi = {10.1007/s10334-025-01296-6}
}
EUVIMED