Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast
Magnetic Resonance Materials in Physics, Biology and Medicine · 2024
DOI: 10.1007/s10334-024-01161-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Gabrio Rizzuti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Utrecht University, Heidelberglaan 8, 3584 CS, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Artifacts, Motion. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.
Abstract (Originalsprache)
Object In a typical MR session, several contrasts are acquired. Due to the sequential nature of the data acquisition process, the patient may experience some discomfort at some point during the session, and start moving. Hence, it is quite common to have MR sessions where some contrasts are well-resolved, while other contrasts exhibit motion artifacts. Instead of repeating the scans that are corrupted by motion, we introduce a reference-guided retrospective motion correction scheme that takes advantage of the motion-free scans, based on a generalized rigid registration routine. Materials and methods We focus on various existing clinical 3D brain protocols at 1.5 Tesla MRI based on Cartesian sampling. Controlled experiments with three healthy volunteers and three levels of motion are performed.
Results
Radiological inspection confirms that the proposed method consistently ameliorates the corrupted scans. Furthermore, for the set of specific motion tests performed in this study, the quality indexes based on PSNR and SSIM shows only a modest decrease in correction quality as a function of motion complexity.
Discussion
While the results on controlled experiments are positive, future applications to patient data will ultimately clarify whether the proposed correction scheme satisfies the radiological requirements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Utrecht University, Heidelberglaan 8, 3584 CS, Utrecht, The Netherlands.
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
- Centrum Wiskunde & Informatica, Science Park Amsterdam 123, 1098 XG, Amsterdam, The Netherlands.
- Universitair Medisch Centrum Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. a.sbrizzi@umcutrecht.nl.
Förderung
- ZonMw
Zitieren
APA
Rizzuti, G., Schakel, T., Huttinga, N. R. F., Dankbaar, J. W., van Leeuwen, T., & Sbrizzi, A. (2024). Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01161-y
Vancouver
Rizzuti G, Schakel T, Huttinga NRF, Dankbaar JW, van Leeuwen T, Sbrizzi A. Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01161-y
BibTeX
@article{Rizzuti2024,
author = {Rizzuti, Gabrio and Schakel, Tim and Huttinga, Niek R F and Dankbaar, Jan Willem and van Leeuwen, Tristan and Sbrizzi, Alessandro},
title = {Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2024},
doi = {10.1007/s10334-024-01161-y}
}
EUVIMED