EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of accelerated motion-compensated 3d water/fat late gadolinium enhanced MR for atrial wall imaging

Camila Munoz, Iain Sim, Radhouene Neji, Karl P Kunze, Pier-Giorgio Masci, Michaela Schmidt, Mark O'Neill, Steven Williams, René M Botnar, Claudia Prieto

Magnetic Resonance Materials in Physics, Biology and Medicine · 2021-12 · 34 (6) · 877-887

DOI: 10.1007/s10334-021-00935-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 24.06.2021. Verfasst von Camila Munoz und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK. cami…. Hauptthemen laut MEDLINE: Contrast Media, Gadolinium. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Health Research, Engineering and Physical Sciences Research Council, Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

3D late gadolinium enhancement (LGE) imaging is a promising non-invasive technique for the assessment of atrial fibrosis. However, current techniques result in prolonged and unpredictable scan times and high rates of non-diagnostic images. The purpose of this study was to compare the performance of a recently proposed accelerated respiratory motion-compensated 3D water/fat LGE technique with conventional 3D LGE for atrial wall imaging. Materials and methods 18 patients (age: 55.7±17.1 years) with atrial fibrillation underwent conventional diaphragmatic navigator gated inversion recovery (IR)-prepared 3D LGE (dNAV) and proposed image-navigator motion-corrected water/fat IR-prepared 3D LGE (iNAV) imaging. Images were assessed for image quality and presence of fibrosis by three expert observers. The scan time for both techniques was recorded.

Results

Image quality scores were improved with the proposed compared to the conventional method (iNAV: 3.1 ± 1.0 vs. dNAV: 2.6 ± 1.0, p = 0.0012, with 1: Non-diagnostic to 4: Full diagnostic). Furthermore, scan time for the proposed method was significantly shorter with a 59% reduction is scan time (4.5 ± 1.2 min vs. 10.9 ± 3.9 min, p < 0.0001). The images acquired with the proposed method were deemed as inconclusive less frequently than the conventional images (expert 1/expert 2: 4/7 dNAV and 2/4 iNAV images inconclusive).

Discussion

The motion-compensated water/fat LGE method enables atrial wall imaging with diagnostic quality comparable to the current conventional approach with a significantly shorter scan of about 5 min.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaGadoliniumAdultAgedHumansImaging, Three-DimensionalMagnetic Resonance ImagingMiddle AgedWater

Stichwörter der Autor:innen

3D atrial LGERespiratory motion-correctionWater/fat LGE

Substanzen

Contrast MediaWaterGadolinium

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK. camila.munoz@kcl.ac.uk.
  • School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK.
  • Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.
  • Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.

Förderung

  • National Institute for Health Research
  • Engineering and Physical Sciences Research Council
  • Medical Research Council
  • British Heart Foundation
  • Wellcome Trust

Zitieren

APA

Munoz, C., Sim, I., Neji, R., Kunze, K. P., Masci, P. G., Schmidt, M., O'Neill, M., Williams, S., Botnar, R. M., & Prieto, C. (2021). Evaluation of accelerated motion-compensated 3d water/fat late gadolinium enhanced MR for atrial wall imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 34(6), 877-887. https://doi.org/10.1007/s10334-021-00935-y

Vancouver

Munoz C, Sim I, Neji R, Kunze KP, Masci PG, Schmidt M, et al. Evaluation of accelerated motion-compensated 3d water/fat late gadolinium enhanced MR for atrial wall imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. 2021;34(6):877-887. doi:10.1007/s10334-021-00935-y

BibTeX
@article{Munoz2021,
  author = {Munoz, Camila and Sim, Iain and Neji, Radhouene and Kunze, Karl P and Masci, Pier-Giorgio and Schmidt, Michaela and O'Neill, Mark and Williams, Steven and Botnar, René M and Prieto, Claudia},
  title = {Evaluation of accelerated motion-compensated 3d water/fat late gadolinium enhanced MR for atrial wall imaging},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2021},
  volume = {34},
  number = {6},
  pages = {877--887},
  doi = {10.1007/s10334-021-00935-y}
}
Kostenlos starten →