An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging
Magnetic Resonance Materials in Physics, Biology and Medicine · 2015-10 · 28 (5) · 459-472
DOI: 10.1007/s10334-015-0482-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 26.02.2015. Verfasst von Guobin Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Medical Physics, University Medical Center Freiburg, Breisacher Straße 60a, 79106, Freiburg, Germany. guobin.li@uniklinik-fr…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: In most half-Fourier imaging methods, explicit phase replacement is used. In combination with parallel imaging, or compressed sensing, half-Fourier reconstruction is usually performed in a separate step. The purpose of this paper is to report that integration of half-Fourier reconstruction into iterative reconstruction minimizes reconstruction errors. MATERIALS AND METHODS: The L1-norm phase constraint for half-Fourier imaging proposed in this work is compared with the L2-norm variant of the same algorithm, with several typical half-Fourier reconstruction methods. Half-Fourier imaging with the proposed phase constraint can be seamlessly combined with parallel imaging and compressed sensing to achieve high acceleration factors. RESULTS: In simulations and in in-vivo experiments half-Fourier imaging with the proposed L1-norm phase constraint enables superior performance both reconstruction of image details and with regard to robustness against phase estimation errors. CONCLUSION: The performance and feasibility of half-Fourier imaging with the proposed L1-norm phase constraint is reported. Its seamless combination with parallel imaging and compressed sensing enables use of greater acceleration in 3D MR imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Breisacher Straße 60a, 79106, Freiburg, Germany. guobin.li@uniklinik-freiburg.de.
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Breisacher Straße 60a, 79106, Freiburg, Germany.
- Siemens Healthcare, Erlangen, Germany.
- Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.
Zitieren
APA
Li, G., Hennig, J., Raithel, E., Büchert, M., Paul, D., Korvink, J. G., & Zaitsev, M. (2015). An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(5), 459-472. https://doi.org/10.1007/s10334-015-0482-7
Vancouver
Li G, Hennig J, Raithel E, Büchert M, Paul D, Korvink JG, et al. An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. 2015;28(5):459-472. doi:10.1007/s10334-015-0482-7
BibTeX
@article{Li2015,
author = {Li, Guobin and Hennig, Jürgen and Raithel, Esther and Büchert, Martin and Paul, Dominik and Korvink, Jan G and Zaitsev, Maxim},
title = {An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2015},
volume = {28},
number = {5},
pages = {459--472},
doi = {10.1007/s10334-015-0482-7}
}