Blood volume deficit in postural orthostatic tachycardia syndrome assessed by semiautomated carbon monoxide rebreathing
Clinical Autonomic Research · 2025
DOI: 10.1007/s10286-024-01091-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Autonomic Research, 2025. Verfasst von Surat Kulapatana und 10 weiteren Autor:innen. Beteiligte Einrichtung: Autonomic Dysfunction Center, Department of Medicine, Division of Clinical Pharmacology, Vanderbilt University Medical Center, 1161 21 Avenue South, …. Hauptthemen laut MEDLINE: Postural Orthostatic Tachycardia Syndrome, Carbon Monoxide, Blood Volume. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute, Dysautonomia Foundation.
Abstract (Originalsprache)
Purpose
The semiautomated carbon monoxide (CO) rebreathing method has been introduced as a noninvasive and radiation-free blood volume estimation method. We tested whether the semiautomated CO rebreathing method can detect the blood volume deficit in postural orthostatic tachycardia syndrome (POTS). In addition, we explored the relationship between blood volume estimated from CO rebreathing and body impedance. Patients and methods We recruited 53 subjects (21 female patients with POTS, 19 healthy female participants, and 13 healthy male participants) to record blood volumes and hemodynamic data. Blood volumes were measured by CO rebreathing and segmental body impedance. Linear regression models to predict normal values of red blood cell volume (RBCV), plasma volume (PV), and total blood volume (BV) were developed. Percentage deviations from the predicted normal volumes were calculated.
Results
Patients with POTS had lower RBCV (25.18 ± 3.95 versus 28.57 ± 3.68 mL/kg, p = 0.008, patients with POTS versus healthy female participants), BV (64.53 ± 10.02 versus 76.78 ± 10.00 mL/kg, p < 0.001), and BV deviation (−13.92 ± 10.38% versus −0.02 ± 10.18%, p < 0.001). Patients with POTS had higher supine heart rate (HR) (84 ± 14 versus 69 ± 11 bpm, p < 0.001) and upright HR (123 ± 23 versus 89 ± 22 bpm, p < 0.001). We found a correlation between BV deviation and upright HR in patients with POTS ( r = −0.608, p = 0.003), but not in healthy participants. Volumes from the CO rebreathing and body impedance were well correlated ( r = 0.629, p < 0.001).
Conclusions
The CO rebreathing method can detect BV deficit, as well as the RBCV deficit in patients with POTS. The negative correlation between BV deviation and upright HR indicates that hypovolemia is one of the pathophysiological causes of POTS. Correlations between body impedance and CO rebreathing volume suggest its usefulness for measurements of volume changes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Autonomic Dysfunction Center, Department of Medicine, Division of Clinical Pharmacology, Vanderbilt University Medical Center, 1161 21 Avenue South, Suite S3116 MCN, Nashville, TN, 37232‑2600, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
- Department of Physiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, 10700, Thailand.
- Clinical Research Unit, myDoctorAngel Sagl, Bioggio, Switzerland.
- Humanitas Clinical and Research Center- IRCCS, Via Alessandro Manzoni, 56, Rozzano, Italy.
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy.
Förderung
- NHLBI NIH HHS
- National Heart, Lung, and Blood Institute
- Dysautonomia Foundation
Zitieren
APA
Kulapatana, S., Urechie, V., Rigo, S., Mohr, A., Vance, Y. A., Okamoto, L. E., Gamboa, A., Shibao, C., Biaggioni, I., Furlan, R., & Diedrich, A. (2025). Blood volume deficit in postural orthostatic tachycardia syndrome assessed by semiautomated carbon monoxide rebreathing. Clinical Autonomic Research. https://doi.org/10.1007/s10286-024-01091-8
Vancouver
Kulapatana S, Urechie V, Rigo S, Mohr A, Vance YA, Okamoto LE, et al. Blood volume deficit in postural orthostatic tachycardia syndrome assessed by semiautomated carbon monoxide rebreathing. Clinical Autonomic Research. 2025. doi:10.1007/s10286-024-01091-8
BibTeX
@article{Kulapatana2025,
author = {Kulapatana, Surat and Urechie, Vasile and Rigo, Stefano and Mohr, Abigail and Vance, Yuliya A and Okamoto, Luis E and Gamboa, Alfredo and Shibao, Cyndya and Biaggioni, Italo and Furlan, Raffaello and Diedrich, André},
title = {Blood volume deficit in postural orthostatic tachycardia syndrome assessed by semiautomated carbon monoxide rebreathing},
journal = {Clinical Autonomic Research},
year = {2025},
doi = {10.1007/s10286-024-01091-8}
}
EUVIMED