Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 17.11.2026. Verfasst von Paul Soliman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University Medical Center, Nashville, TN, USA. paul.s.soliman@vanderbilt.edu. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate estimation of the future liver remnant (FLR) is essential for planning hepatectomy and portal vein embolization (PVE), yet conventional calculation relies on manual segmentation that is time-intensive and dependent on specialized workstations. Thus, LIVSEG was developed as a single-page web application that streams DICOM or NIfTI imaging to a cloud GPU running TotalSegmentator nnU-Net models for automated Couinaud-segment and hepatic-lesion segmentation, with an integrated editor for human review. In a cohort of 60 patients (38 living liver donors, 22 PVE patients; 82 scans), the absolute difference between automated and manual FLR was 3.24 ± 2.69 percentage points (pp) in donors and 4.49 ± 5.14 pp across PVE scans, and the two methods were statistically equivalent within a ± 5 pp margin in all cohorts. Using institutional FLR thresholds, LIVSEG and manual volumetry yielded concordant classifications in 79 of 82 scans (96.3%). Inference was completed in two minutes per case at a GPU cost of $0.014–0.026 per study. LIVSEG allows models to reach clinical workflows while retaining human oversight.

Schlagwörter

Stichwörter der Autor:innen

Artificial intelligenceEmbolizationHepatectomyLiver transplantationSegmentationVolumetry

Autor:innen und Institutionen

  • Vanderbilt University Medical Center, Nashville, TN, USA. paul.s.soliman@vanderbilt.edu.
  • Vanderbilt University Medical Center, Nashville, TN, USA.
  • Department of Radiology, Division of Interventional Radiology, Vanderbilt University Medical Center, Nashville, TN, USA.

Zitieren

APA

Soliman, P., Jones, L., Hall, A., Abdalla, O., Marsala, A., Brown, D., & Case, M. D. (2026). LIVSEG: A Cloud-GPU Web Application for Automated Future Liver Remnant Estimation. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-026-02538-2

Vancouver

Soliman P, Jones L, Hall A, Abdalla O, Marsala A, Brown D, et al. LIVSEG: A Cloud-GPU Web Application for Automated Future Liver Remnant Estimation. Journal of Imaging Informatics in Medicine. 2026. doi:10.1007/s10278-026-02538-2

BibTeX
@article{Soliman2026,
  author = {Soliman, Paul and Jones, Luke and Hall, Andre and Abdalla, Omar and Marsala, Andrew and Brown, Daniel and Case, Meaghan Dendy},
  title = {LIVSEG: A Cloud-GPU Web Application for Automated Future Liver Remnant Estimation},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2026},
  doi = {10.1007/s10278-026-02538-2}
}
Kostenlos starten →