Energy-Efficient Usage of CT Scanners Through Mathematically Optimized Examination Scheduling
Journal of Imaging Informatics in Medicine · 07.07.2026
DOI: 10.1007/s10278-026-02040-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 07.07.2026. Verfasst von Martin Segeroth und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital Basel, Basel, Switzerland. martin.segeroth@usb.ch. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Medical imaging devices are large consumers of electricity. This study aims to estimate potential energy savings through optimized CT examination scheduling using an ideal (hypothetical) lower-bound and a clinically realistic model. Examination timestamps and power consumption data of all CT examinations (n = 13,153) performed on three CT scanners in a tertiary care radiology department across 261 workdays in 2015 were retrospectively analyzed. CT examination scheduling was optimized using binary linear programming to minimize total scanner energy consumption. Two models were evaluated: a lower-bound model (LB model) allowing shutdown of all nonemergency scanners and a realistic model (R model) keeping one additional routine scanner continuously available during operating hours. Optimization problems were solved within seconds for each workday. Compared with observed clinical operation, the LB model achieved a reduction in daily energy consumption of 34.8% (34.2-35.5%), whereas the R model yielded an 11.0% (10.7-11.3%) reduction. These corresponded to estimated annual energy savings of 10,933 kWh and 3,460 kWh, respectively. For the R model, this translated to approximately $692 in annual cost savings and a reduction of 998 kgCO2-equivalent emissions, while preserving clinically feasible scanner availability. Optimization-based CT examination scheduling can substantially reduce energy consumption without additional hardware. Even under realistic workflow constraints, meaningful sustainability and cost benefits were observed. Automated, optimization-guided CT scheduling may represent a practical strategy to reduce the environmental footprint of radiology departments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University Hospital Basel, Basel, Switzerland. martin.segeroth@usb.ch.
- University of Freiburg, Freiburg im Breisgau, Germany.
- Department of Radiology, University Hospital Basel, Basel, Switzerland.
Zitieren
APA
Segeroth, M., Nurkanović, A., Indrakanti, A., Vosshenrich, J., Merkle, E. M., Diehl, M., & Heye, T. (2026). Energy-Efficient Usage of CT Scanners Through Mathematically Optimized Examination Scheduling. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-026-02040-9
Vancouver
Segeroth M, Nurkanović A, Indrakanti A, Vosshenrich J, Merkle EM, Diehl M, et al. Energy-Efficient Usage of CT Scanners Through Mathematically Optimized Examination Scheduling. Journal of Imaging Informatics in Medicine. 2026. doi:10.1007/s10278-026-02040-9
BibTeX
@article{Segeroth2026,
author = {Segeroth, Martin and Nurkanović, Armin and Indrakanti, Ashraya and Vosshenrich, Jan and Merkle, Elmar M and Diehl, Moritz and Heye, Tobias},
title = {Energy-Efficient Usage of CT Scanners Through Mathematically Optimized Examination Scheduling},
journal = {Journal of Imaging Informatics in Medicine},
year = {2026},
doi = {10.1007/s10278-026-02040-9}
}
EUVIMED