EUVIMEDEUVIMED entdecken
Crossref

Pronation-Supination Standardization Using a Data-Driven Statistical Pose Model

Paul-Emmanuel Edeline, Basile Longo, Aziliz Guezou-Philippe, Ehouarn Maguet, Hoel Letissier, Théo Aguilar Vidal, Marc-Olivier Gauci, Guillaume Dardenne, Valérie Burdin

Journal of Imaging Informatics in Medicine · 20.05.2026

DOI: 10.1007/s10278-026-01992-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 20.05.2026. Verfasst von Paul-Emmanuel Edeline und 8 weiteren Autor:innen. Beteiligte Einrichtung: LaTIM, INSERM U1101, Brest, France. paul-emmanuel.edeline@imt-atlantique.fr. Die Arbeit nennt 27 Literaturangaben. Gefördert von: Agence Nationale de la Recherche.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Image-based clinical measurements of the forearm can be biased when pronation-supination (PS) is not properly accounted for when repositioning during surgery. We therefore aim to build and validate an original data-driven joint statistical pose model (SPM) combining both radius and ulna, that supports a linear angle-to-pose PS model, for computer-assisted PS standardization (CAPSS). We built an SPM from 88 forearm CT scans by registering ulnas to a common template and performing PCA on the coupled radius-ulna pose. We fitted the SPM to 25 PS sweeps acquired on optically tracked cadavers (4 specimens) and compared it with a fixed-axis rotation baseline, using translational error (TE), rotational error (RE), and mesh RMSE versus optical tracking. Spearman correlations between SPM modes and PS angle were used to identify PS-related modes, and further derive a linear angle-to-pose model evaluated by specimen-wise leave-one-out. The SPM reproduced cadaveric PS trajectories with 0.12 mm mean mesh RMSE, 0.12 mm TE, and 0.08 ∘ RE, versus 2.5 mm RMSE, 1.9 mm TE, and 5.3 ∘ RE for the fixed-axis baseline. The linear angle-to-pose model using only strongly PS-related modes reconstructed unseen sweeps with 1.9 mm RMSE, 1.6 mm TE, and 1.0 ∘ RE. Forearm PS is better captured as a combination of coupled radius-ulna pose modes than as a single fixed-axis rotation. In this preclinical validation on intact forearms, these modes supported a linear angle-to-pose model enabling automated pose standardization without subject-specific calibration. These findings support the feasibility of computer-assisted PS standardization for pose-consistent 3D morphometric analysis, while direct application to pathological anatomy and clinical surgical planning requires dedicated validation.

Schlagwörter

Stichwörter der Autor:innen

CT-based measurement standardizationComputational surgeryDistal radiusForearm kinematicsPronation-supinationStatistical pose model (SPM)

Autor:innen und Institutionen

  • LaTIM, INSERM U1101, Brest, France. paul-emmanuel.edeline@imt-atlantique.fr.
  • IMT Atlantique, Brest, France. paul-emmanuel.edeline@imt-atlantique.fr.
  • LaTIM, INSERM U1101, Brest, France.
  • Université de Bretagne Occidentale, Brest, France.
  • IMT Atlantique, Brest, France.
  • CHU de Brest, Brest, France.

Förderung

  • Agence Nationale de la Recherche

Zitieren

APA

Edeline, P. E., Longo, B., Guezou-Philippe, A., Maguet, E., Letissier, H., Aguilar Vidal, T., Gauci, M. O., Dardenne, G., & Burdin, V. (2026). Pronation-Supination Standardization Using a Data-Driven Statistical Pose Model. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-026-01992-2

Vancouver

Edeline PE, Longo B, Guezou-Philippe A, Maguet E, Letissier H, Aguilar Vidal T, et al. Pronation-Supination Standardization Using a Data-Driven Statistical Pose Model. Journal of Imaging Informatics in Medicine. 2026. doi:10.1007/s10278-026-01992-2

BibTeX
@article{Edeline2026,
  author = {Edeline, Paul-Emmanuel and Longo, Basile and Guezou-Philippe, Aziliz and Maguet, Ehouarn and Letissier, Hoel and Aguilar Vidal, Théo and Gauci, Marc-Olivier and Dardenne, Guillaume and Burdin, Valérie},
  title = {Pronation-Supination Standardization Using a Data-Driven Statistical Pose Model},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2026},
  doi = {10.1007/s10278-026-01992-2}
}
Kostenlos starten →