DECTGoutSys: Reducing False Positive Gout Diagnoses via a Machine Vision Pipeline for Crystal Tophi Identification+Classification in Dual-Energy Computed Tomography (DECT)

Riel Castro-Zunti, Yunjung Choi, Younhee Choi, Hee Suk Chae, Gong Yong Jin, Eun Hae Park, Seok-Bum Ko

Journal of Imaging Informatics in Medicine · 2025

DOI: 10.1007/s10278-025-01703-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, 2025. Verfasst von Riel Castro-Zunti und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK, S7N 5A9, Canada. Hauptthemen laut MEDLINE: Gout, Tomography, X-Ray Computed, Machine Learning, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Sciences and Engineering Research Council of Canada, National Research Foundation of Korea, Biomedical Research Institute, Jeonbuk National University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gout is the world's foremost chronic inflammatory arthritis. Dual-energy computed tomography (DECT) images tophi-monosodium urate (MSU) crystal deposits that indicate gout-as an easily recognizable green color, facilitating high sensitivity. However, tophi-like regions ("artifacts") may be found in healthy controls, degrading specificity. To mitigate false positives, we propose the first automated system to localize MSU-presenting crystal deposits from DECT and classify them as gouty tophi or artifacts. Our solution, developed using 47 gout and 27 control patient scans, is three-stage. First, a computer vision algorithm crops green regions of interest (RoIs) from a patient's DECT scan frames and filters obvious false positives. Next, extracted RoIs are classified as tophi or artifact via one of three fine-tuned deep learning models; one model is trained to predict "small" RoIs, another "medium," and the third predicts "large" RoIs. Size thresholds are based on pixel area quartile statistics. Patient-level gout versus control classification is made via a machine learning system trained using a suite of features calculated from the outcomes of the RoI classifiers. Using 6-fold cross-validation, the proposed pipeline achieved a patient-level diagnostic accuracy, sensitivity, and specificity of 91.89%, 87.23%, and 100.00%. Using confidence values derived from the majority vote of RoI predictions, the best area under the receiver operator characteristics curve (ROC AUC) is 97.16%. The best RoI-level classifiers achieved mean tophus versus artifact accuracy, sensitivity, specificity, and ROC AUC of 89.61%, 85.42%, 93.70%, and 92.72%. Results demonstrate that machine/deep learning facilitates high-specificity gout diagnoses while maintaining respectable sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GoutTomography, X-Ray ComputedMachine LearningRadiographic Image Interpretation, Computer-AssistedRadiography, Dual-Energy Scanned ProjectionHumansFalse Positive ReactionsUric AcidSensitivity and SpecificityAlgorithmsArtifactsDeep Learning

Stichwörter der Autor:innen

ClassificationConvolutional neural networksGoutLocalizationMachine learning

Substanzen

Uric Acid

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK, S7N 5A9, Canada.
  • Research Institute of Clinical Medicine, Jeonbuk National University-Biomedical Research Institute, Jeonbuk National University Hospital, 54907, Jeonju, Jeollabuk-do, Republic of Korea.
  • Department of Internal Medicine, Division of Rheumatology, Jeonbuk National University Medical School, 54896, Jeonju, Jeollabuk-do, South Korea.
  • Department of Obstetrics and Gynecology, Jeonbuk National University-Biomedical Research Institute, Jeonbuk National University Hospital, 54907, Jeonju, Republic of Korea.
  • Department of Radiology, Jeonbuk National University-Biomedical Research Institute, Jeonbuk National University Hospital, 54907, Jeonju, Republic of Korea.
  • Research Institute of Clinical Medicine, Jeonbuk National University-Biomedical Research Institute, Jeonbuk National University Hospital, 54907, Jeonju, Jeollabuk-do, Republic of Korea. mbgracie@gmail.com.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • National Research Foundation of Korea
  • Biomedical Research Institute, Jeonbuk National University Hospital

Zitieren

APA

Castro-Zunti, R., Choi, Y., Choi, Y., Chae, H. S., Jin, G. Y., Park, E. H., & Ko, S. B. (2025). DECTGoutSys: Reducing False Positive Gout Diagnoses via a Machine Vision Pipeline for Crystal Tophi Identification+Classification in Dual-Energy Computed Tomography (DECT). Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-025-01703-3

Vancouver

Castro-Zunti R, Choi Y, Choi Y, Chae HS, Jin GY, Park EH, et al. DECTGoutSys: Reducing False Positive Gout Diagnoses via a Machine Vision Pipeline for Crystal Tophi Identification+Classification in Dual-Energy Computed Tomography (DECT). Journal of Imaging Informatics in Medicine. 2025. doi:10.1007/s10278-025-01703-3

BibTeX
@article{CastroZunti2025,
  author = {Castro-Zunti, Riel and Choi, Yunjung and Choi, Younhee and Chae, Hee Suk and Jin, Gong Yong and Park, Eun Hae and Ko, Seok-Bum},
  title = {DECTGoutSys: Reducing False Positive Gout Diagnoses via a Machine Vision Pipeline for Crystal Tophi Identification+Classification in Dual-Energy Computed Tomography (DECT)},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2025},
  doi = {10.1007/s10278-025-01703-3}
}
Kostenlos starten →