Comparative Analysis of U-Net and U-Net3 + for Retinal Exudate Segmentation: Performance Evaluation Across Regions
Journal of Imaging Informatics in Medicine · 2025
DOI: 10.1007/s10278-025-01419-4 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Imaging Informatics in Medicine, 2025. Verfasst von Yeong Hun Kang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, College of IT Convergence, Gachon University, Seongnam, Korea. Hauptthemen laut MEDLINE: Diabetic Retinopathy, Exudates and Transudates, Deep Learning, Retina. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Diabetic retinopathy is a major complication of diabetes, with its prevalence nearly doubling to approximately 10.5% by 2021. Exudates, the characteristic lesions of diabetic retinopathy, are crucial for assessing disease progression and severity. The location and distribution of these exudates can affect various regions of the retina, necessitating a detailed regional analysis of lesions. To address this need, this study aimed to evaluate the performance of exudate detection in fundus images across various regions, including perivascular and extravascular areas, perifoveal and extrafoveal regions, and in quadrants defined relative to the fovea. We employed U-net and U-net3 + deep learning models for validation, evaluating their performance using accuracy, sensitivity, specificity, and Dice score. Overall, the U-net3 + model outperformed the U-net model. Therefore, the performance evaluation was based on the results from the U-net3 + model. Comparing the detection performance across perivascular versus extravascular and perifoveal versus extrafoveal regions, the U-net3 + model achieved highest Dice score in the extravascular (87.96% [± 5.80]) and perifoveal areas (88.03% [± 5.86]). Additionally, superior sensitivity and Dice scores were observed in the top-left and top-right quadrants. Future research is anticipated to show that deep learning-based automatic exudate detection will enhance diagnostic accuracy and efficiency, leading to better treatment and prognosis in patients with diabetic retinopathy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, College of IT Convergence, Gachon University, Seongnam, Korea.
- Gachon Biomedical & Convergence Institute, Gachon University, Gil Medical Center, 13 Incheon, Republic of Korea.
- Department of Biomedical Engineering, College of IT Convergence, Gachon University, Seongnam, Korea. kimkg@gachon.ac.kr.
- Department of Biomedical Engineering, College of Medicine, Gachon University, Gil Medical 8 Center, 38-13 3Beon-Gil, Namdong-Gu, Incheon, 21565, Korea. kimkg@gachon.ac.kr.
- Department of Health Science & Technology, Gachon Advanced Institute for Health Science & Technology 10 (GAIHIST), Gachon University, Lee Gil Ya Cancer and Diabetes Institute, 155 Gaetbeol-Ro, 11 Yeonsu-Gu, Incheon, Kor…
Zitieren
APA
Kang, Y. H., Kim, Y. J., & Kim, K. G. (2025). Comparative Analysis of U-Net and U-Net3 + for Retinal Exudate Segmentation: Performance Evaluation Across Regions. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-025-01419-4
Vancouver
Kang YH, Kim YJ, Kim KG. Comparative Analysis of U-Net and U-Net3 + for Retinal Exudate Segmentation: Performance Evaluation Across Regions. Journal of Imaging Informatics in Medicine. 2025. doi:10.1007/s10278-025-01419-4
BibTeX
@article{Kang2025,
author = {Kang, Yeong Hun and Kim, Young Jae and Kim, Kwang Gi},
title = {Comparative Analysis of U-Net and U-Net3 + for Retinal Exudate Segmentation: Performance Evaluation Across Regions},
journal = {Journal of Imaging Informatics in Medicine},
year = {2025},
doi = {10.1007/s10278-025-01419-4}
}
EUVIMED