EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the Image Quality of Digitally Reconstructed Radiographs from Chest CT

Olivier T Paalvast, Omar Hertgers, Merlijn Sevenster, Hildo J Lamb

Journal of Imaging Informatics in Medicine · 2025

DOI: 10.1007/s10278-025-01406-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, 2025. Verfasst von Olivier T Paalvast und 3 weiteren Autor:innen. Beteiligte Einrichtung: Leiden University Medical Center (LUMC), Leiden, the Netherlands. o.t.paalvast@lumc.nl. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Thoracic, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Philips Medical Systems.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rising computed tomography (CT) workloads require more efficient image interpretation methods. Digitally reconstructed radiographs (DRRs), generated from CT data, may enhance workflow efficiency by enabling faster radiological assessments. Various techniques exist for generating DRRs. We conducted a pilot study to explore which DRR technique best approaches the image quality of chest X-Rays (CXR). We quantitatively and qualitatively compared four DRR techniques. A retrospective convenience sample of 217 patients who underwent both ultra-low-dose (ULD) chest CT and CXR was used. Four DRRs were generated per ULDCT, and CheXNet, a neural network trained to detect 14 diseases, was applied to CXRs and DRRs to compute area under the curve (AUC) scores. For qualitative assessment, six radiologists rated the image quality of the four DRRs generated from six ULDCTs on a Likert scale from 1 to 6 (‘not diagnostic quality’ to ‘diagnostic quality’) and provided feedback, which was analysed using inductive category development. CheXNet’s AUC for CXRs was 0.80, while DRR techniques ranged from 0.75 to 0.82 ( p > 0.26). Radiologists rated the diagnostic quality of the DRRs between 3.0 and 3.5 on average. The SoftMip technique scored highest in both the quantitative (AUC = 0.82) and the qualitative (score = 3.5) evaluation. DRRs showed comparable disease detection performance to CXRs, suggesting non-inferiority. However, radiologists expressed concerns about DRR image quality, particularly in terms of resolution, noise, and overall look-and-feel. Addressing these limitations with advanced techniques may further align DRRs with the diagnostic standards of CXRs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiography, ThoracicRadiographic Image Interpretation, Computer-AssistedHumansRetrospective StudiesMalePilot ProjectsFemaleMiddle AgedAgedNeural Networks, ComputerAdultAged, 80 and over

Stichwörter der Autor:innen

Artificial intelligenceChest imagingDigitally reconstructed radiographsImage qualityUltra-low-dose CT

Autor:innen und Institutionen

  • Leiden University Medical Center (LUMC), Leiden, the Netherlands. o.t.paalvast@lumc.nl.
  • Leiden University Medical Center (LUMC), Leiden, the Netherlands.
  • Royal Philips B.V., Amsterdam, the Netherlands.

Förderung

  • Philips Medical Systems

Zitieren

APA

Paalvast, O. T., Hertgers, O., Sevenster, M., & Lamb, H. J. (2025). Assessing the Image Quality of Digitally Reconstructed Radiographs from Chest CT. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-025-01406-9

Vancouver

Paalvast OT, Hertgers O, Sevenster M, Lamb HJ. Assessing the Image Quality of Digitally Reconstructed Radiographs from Chest CT. Journal of Imaging Informatics in Medicine. 2025. doi:10.1007/s10278-025-01406-9

BibTeX
@article{Paalvast2025,
  author = {Paalvast, Olivier T and Hertgers, Omar and Sevenster, Merlijn and Lamb, Hildo J},
  title = {Assessing the Image Quality of Digitally Reconstructed Radiographs from Chest CT},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2025},
  doi = {10.1007/s10278-025-01406-9}
}
Kostenlos starten →