EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

A Comparison of Deep Learning vs. Dental Implantologists in Cone-Beam Computed Tomography-Based Bone Quality Classification

Thatphong Pornvoranant, Wannakamon Panyarak, Kittichai Wantanajittikul, Arnon Charuakkra, Pimduen Rungsiyakull, Pisaisit Chaijareenont

Journal of Imaging Informatics in Medicine · 18.11.2024 · 38 (4) · 2462-2471

DOI: 10.1007/s10278-024-01317-1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Imaging Informatics in Medicine, online erschienen am 18.11.2024. Verfasst von Thatphong Pornvoranant und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Dentistry, Faculty of Dentistry, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Oral and Maxillofacial Surgeons, Deep Learning, Bone Density. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Chiang Mai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bone quality assessment is crucial for pre-surgical implant planning, influencing both implant design and drilling protocol selection. The Lekholm and Zarb (L&Z) classification, which categorizes bone quality into four types based on cortical bone width and trabecular bone density using cone-beam computed tomography (CBCT) data, lacks quantitative guidelines, leading to subjective interpretations. This study aimed to compare the performance of deep learning (DL)-based approaches against human examiners in assessing bone quality, according to the L&Z classification, using CBCT images. A dataset of 1100 CBCT cross-sectional slices was classified into four bone types by two oral and maxillofacial radiologists. Five pre-trained DL models were trained on 1000 images using MATLAB®, with 100 images reserved for testing. Inception-ResNet-v2 achieved the highest accuracy (86.00%) with a learning rate of 0.001. The performance of Inception-ResNet-v2 was then compared to that of 23 residency students and two experienced implantologists. The DL model outperformed human assessors across all parameters, demonstrating excellent precision and recall, with F1-scores exceeding 75%. Notably, residency students and one implantologist struggled to distinguish bone type 2, with low recall rates (48.15% and 40.74%, respectively). In conclusion, the Inception-ResNet-v2 DL model demonstrated superior performance compared to novice implantologists, suggesting its potential as an supplementary tool for cross-sectional bone quality assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyOral and Maxillofacial SurgeonsDeep LearningBone DensityJawRetrospective StudiesObserver VariationHumansRadiologistsInternship and ResidencyDatasets as TopicDental Implants

Stichwörter der Autor:innen

Artificial intelligenceBone quality assessmentCross-sectional imageLekholm and Zarb classificationPre-surgical implant planning

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Graduate School of Dentistry, Faculty of Dentistry, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand.
  • Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand. wanna…
  • Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand. kittichai.wan@cmu.ac.th.
  • Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand.
  • Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Suthep Road, Suthep Sub-District, Mueang, Chiang Mai, 50200, Thailand.

Förderung

  • Chiang Mai University

Zitieren

APA

Pornvoranant, T., Panyarak, W., Wantanajittikul, K., Charuakkra, A., Rungsiyakull, P., & Chaijareenont, P. (2024). A Comparison of Deep Learning vs. Dental Implantologists in Cone-Beam Computed Tomography-Based Bone Quality Classification. Journal of Imaging Informatics in Medicine, 38(4), 2462-2471. https://doi.org/10.1007/s10278-024-01317-1

Vancouver

Pornvoranant T, Panyarak W, Wantanajittikul K, Charuakkra A, Rungsiyakull P, Chaijareenont P. A Comparison of Deep Learning vs. Dental Implantologists in Cone-Beam Computed Tomography-Based Bone Quality Classification. Journal of Imaging Informatics in Medicine. 2024;38(4):2462-2471. doi:10.1007/s10278-024-01317-1

BibTeX
@article{Pornvoranant2024,
  author = {Pornvoranant, Thatphong and Panyarak, Wannakamon and Wantanajittikul, Kittichai and Charuakkra, Arnon and Rungsiyakull, Pimduen and Chaijareenont, Pisaisit},
  title = {A Comparison of Deep Learning vs. Dental Implantologists in Cone-Beam Computed Tomography-Based Bone Quality Classification},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2024},
  volume = {38},
  number = {4},
  pages = {2462--2471},
  doi = {10.1007/s10278-024-01317-1}
}