EUVIMEDEUVIMED entdecken
Crossref

Anionic surfactant and its nanocomposite as corrosion inhibitors for dental implants

Sheerin Masroor, M Z A Rafiquee, Ajay Kumar, Mohd Mobin, Omar Dagdag, Avni Berisha, Mohammad Ehtisham Khan

Odontology · 2025

DOI: 10.1007/s10266-025-01192-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Odontology, 2025. Verfasst von Sheerin Masroor und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, A.N. College, Patliputra University, Patna, 800013, Bihar, India. masroor.sheerin@gmail.com. Hauptthemen laut MEDLINE: Dental Implants, Titanium, Surface-Active Agents, Nanocomposites. Die Arbeit nennt 83 Literaturangaben. Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dental implants are continuously exposed to aggressive oral conditions that can trigger corrosion and compromise their long-term success. In the present work, findings highlight the potential of surfactant nanocomposities (NCs), sodium dodecyl sulfate (SDS) with the titanium oxide (TiO₂) nanoparticals (NPs), which were evaluated as corrosion inhibitors using mild steel as a model substrate in artificial saliva. Electrochemical impedance spectroscopy (EIS) and open circuit potential (OCP) measurements revealed that the SDS-TiO₂ system achieved markedly higher inhibition efficiency than SDS alone, owing to strong adsorption and stable inhibitor-surface interactions. Structural characterization confirmed nanoscale particle size and stability. Transmission electron microscopy (TEM) confirmed nanoscale dimensions (13.9-28.6 nm) and and zeta-sizer analysis revealed a single sharp peak with an approximate size of 17 nm with good stability, supporting its effective performance. The high Eads value ( - 2585.50 kcal/mol) for the SDS-TiO2 NCs system reflects the greater stability (inhibitor/surface interaction) and consequently increases their inhibition efficiencies. Statistical analysis (ANOVA, p < 0.05) further validated the significant improvement in resistance parameters with SDS-TiO₂. Computational modeling (DFT, Monte Carlo (MC), and Molecular Dynamics (MD) simulations) corroborated experimental findings by demonstrating the strong binding affinity of the inhibitor system adsorbed on the surface of Fe (110) by a horizontal orientation. While mild steel was employed as a surrogate, these results highlight the translational promise of SDS-TiO₂ NCs for enhancing corrosion resistance in dental implant environments. Future validation of the present findings on clinically relevant alloys (CP-Ti and Ti-6Al-4 V) is essential to confirm the translational potential of SDS-TiO₂ systems for real-world dental implant applications. This addition strengthens the clinical anchoring of the study by outlining a clear direction for future research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsTitaniumSurface-Active AgentsNanocompositesSodium Dodecyl SulfateCorrosionDielectric SpectroscopySurface PropertiesMicroscopy, Electron, TransmissionMaterials TestingParticle Size

Stichwörter der Autor:innen

BracesCorrosion inhibitionDental implantsSurfactant NMsTitanium alloys

Substanzen

Dental ImplantsTitaniumSurface-Active Agentstitanium dioxideSodium Dodecyl Sulfate

Autor:innen und Institutionen

  • Department of Chemistry, A.N. College, Patliputra University, Patna, 800013, Bihar, India. masroor.sheerin@gmail.com.
  • Faculty of Engineering and Technology, Department of Applied Chemistry, Aligarh Muslim University, Aligarh, 202002, UP, India.
  • Department of Chemistry, School of Applied and Life Sciences and Uttaranchal Institute of Technology, Uttaranchal University, Dehradun, 248007, Uttarakhand, India. ajay.tiwari1591@gmail.com.
  • Centre for Materials Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg, 1710, South Africa.
  • Faculty of Natural and Mathematics Science, Department of Chemistry, University of Prishtina, 10000, Prishtina, Kosovo.
  • Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan, 45142, Saudi Arabia. mekhan@jazanu.edu.sa.

Förderung

  • National Science Foundation

Zitieren

APA

Masroor, S., Rafiquee, M. Z. A., Kumar, A., Mobin, M., Dagdag, O., Berisha, A., & Khan, M. E. (2025). Anionic surfactant and its nanocomposite as corrosion inhibitors for dental implants. Odontology. https://doi.org/10.1007/s10266-025-01192-4

Vancouver

Masroor S, Rafiquee MZA, Kumar A, Mobin M, Dagdag O, Berisha A, et al. Anionic surfactant and its nanocomposite as corrosion inhibitors for dental implants. Odontology. 2025. doi:10.1007/s10266-025-01192-4

BibTeX
@article{Masroor2025,
  author = {Masroor, Sheerin and Rafiquee, M Z A and Kumar, Ajay and Mobin, Mohd and Dagdag, Omar and Berisha, Avni and Khan, Mohammad Ehtisham},
  title = {Anionic surfactant and its nanocomposite as corrosion inhibitors for dental implants},
  journal = {Odontology},
  year = {2025},
  doi = {10.1007/s10266-025-01192-4}
}
Kostenlos starten →