EUVIMEDEUVIMED entdecken
Crossref

The current overview of the devices of temporary anchorage placed on the palatal bone: CBCT study

Seda Kotan, Alaettin Koç, Ayşe Gül Öner Talmaç

Odontology · 2024

DOI: 10.1007/s10266-024-00931-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Odontology, 2024. Verfasst von Seda Kotan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Faculty of Dentistry, Iğdır University, Iğdır, 76000, Turkey. dtsedakotan@gmail.com. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Orthodontic Anchorage Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Temporary anchorage devices (TADs) are frequently applied to different anatomic areas with different protocols to increase skeletal effects and anchorage in orthodontic treatment planning. It has been reported in many literatures that primary stability for orthodontic TADs is significant for long-term survival rate. For this reason, different areas of the palatal region, which has many indications, have been widely used in the studies. In this evaluation where bone quality and thickness are important, density, bone thickness, and fractal dimension (FD) on cone beam computed tomography (CBCT) will provide more predictable clinical results. The aim of this study was to evaluate bone thickness, density, and FD in the palatal region of the first, and second premolars, and first molars. There was a remarkable difference (p < 0.05) between the parameters of FD, thickness and density of bone in the identified areas in the palatal region. In terms of thickness and FD, the 1st premolar region had significantly higher values than the other regions (p < 0.05). In terms of density, the values in the right 1st molar and right 1st premolar regions were significantly higher (p < 0.05). The 1st premolar region is an ideal site for placement of palatal TADs. CBCT-assisted preliminary evaluation of FD value, bone density, and thickness may increase clinical success when selecting the location of TADs to be applied to the palatal bone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyOrthodontic Anchorage ProceduresHumansFemaleMaleBicuspidMolarBone DensityPalate, HardAdolescent

Stichwörter der Autor:innen

Bone densityBone thicknessFractal dimension analysisPalatal TADs

Autor:innen und Institutionen

  • Department of Orthodontics, Faculty of Dentistry, Iğdır University, Iğdır, 76000, Turkey. dtsedakotan@gmail.com.
  • Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Van Yüzüncü Yıl University, Van, Turkey.

Zitieren

APA

Kotan, S., Koç, A., & Öner Talmaç, A. G. (2024). The current overview of the devices of temporary anchorage placed on the palatal bone: CBCT study. Odontology. https://doi.org/10.1007/s10266-024-00931-3

Vancouver

Kotan S, Koç A, Öner Talmaç AG. The current overview of the devices of temporary anchorage placed on the palatal bone: CBCT study. Odontology. 2024. doi:10.1007/s10266-024-00931-3

BibTeX
@article{Kotan2024,
  author = {Kotan, Seda and Koç, Alaettin and Öner Talmaç, Ayşe Gül},
  title = {The current overview of the devices of temporary anchorage placed on the palatal bone: CBCT study},
  journal = {Odontology},
  year = {2024},
  doi = {10.1007/s10266-024-00931-3}
}
Kostenlos starten →