EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility of large-scale in silico transcatheter aortic valve implantation trials using a fast-to-evaluate model

Sabine Verstraeten, Marloes van Driel, Robin Willems, Sai Divi, Martijn Hoeijmakers, Frans van de Vosse, Clemens Verhoosel, Wouter Huberts

Biomechanics and Modeling in Mechanobiology · 2026-10 · 25 (5)

DOI: 10.1007/s10237-026-02136-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 25.09.2026. Verfasst von Sabine Verstraeten und 7 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Eindhoven University of Technology, Dominee Theodor Fliednerstraat 2, 5631 BN, Eindhoven, The Netherlands. sverstraeten06@gma…. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Computer Simulation, Clinical Trials as Topic, Models, Cardiovascular. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although transcatheter aortic valve implantation (TAVI) has been demonstrated to be a successful treatment for aortic stenosis, it remains associated with complications, such as paravalvular leakage (PVL). To address these, TAVI devices continue to undergo iterative development. Integration of in silico trials into the regulatory validation pathway offers a promising approach to accelerate the development and clinical implementation of novel TAVI devices. This study addresses the feasibility of conducting large-scale in silico TAVI trials using a virtual cohort generator (VCG) combined with a fast-to-evaluate model. The objective is to investigate anatomical and procedural predictors of PVL in silico, as was done in an earlier clinical study. A virtual cohort of 500 synthetic aortic stenosis patients was generated, that matched anatomical and demographic characteristics of the clinical population. Using a novel fast-to-evaluate TAVI deployment model, nearly 29,000 simulations were performed across multiple model parameter combinations per patient. Shape and demographic distributions in the in silico trial, remained within the bounds of the clinical study. Among the investigated anatomical parameters, a higher angle between left ventricular outflow tract and ascending aorta was found in patients with significant PLV, in both clinical and virtual cohorts. Additionally, the relationship between PVL and implantation depth appeared highly patient-specific, which is in line with findings in clinical studies. The ability to systematically test multiple TAVI deployments scenarios per patient, which is unfeasible in clinical practice, provides valuable insights for procedure design and optimisation. Overall, the results support the feasibility of implementing large-scale in silico TAVI trials, using the VCG and a fast-to-evaluate model, into the regulatory validation chain.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementComputer SimulationClinical Trials as TopicModels, CardiovascularAortic ValveHumansFeasibility StudiesAortic Valve StenosisFemale

Stichwörter der Autor:innen

Fast-to-evaluate modelsIn silico trialsParavalvular leakageTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Biomedical Engineering, Eindhoven University of Technology, Dominee Theodor Fliednerstraat 2, 5631 BN, Eindhoven, The Netherlands. sverstraeten06@gmail.com.
  • Biomedical Engineering, Eindhoven University of Technology, Dominee Theodor Fliednerstraat 2, 5631 BN, Eindhoven, The Netherlands.
  • Mechanical Engineering, Eindhoven University of Technology, Dominee Theodor Fliednerstraat 2, 5631 BN, Eindhoven, The Netherlands.
  • Synopsys Inc, High Tech Campus 41, 5656 AE, Eindhoven, The Netherlands.
  • Computational Science Lab, Faculty of Science, Informatics Institute, University of Amsterdam, Science Park 900, 1098 XH, Amsterdam, The Netherlands.

Förderung

  • Horizon 2020 Framework Programme

Zitieren

APA

Verstraeten, S., van Driel, M., Willems, R., Divi, S., Hoeijmakers, M., van de Vosse, F., Verhoosel, C., & Huberts, W. (2026). Feasibility of large-scale in silico transcatheter aortic valve implantation trials using a fast-to-evaluate model. Biomechanics and Modeling in Mechanobiology, 25(5). https://doi.org/10.1007/s10237-026-02136-9

Vancouver

Verstraeten S, van Driel M, Willems R, Divi S, Hoeijmakers M, van de Vosse F, et al. Feasibility of large-scale in silico transcatheter aortic valve implantation trials using a fast-to-evaluate model. Biomechanics and Modeling in Mechanobiology. 2026;25(5). doi:10.1007/s10237-026-02136-9

BibTeX
@article{Verstraeten2026,
  author = {Verstraeten, Sabine and van Driel, Marloes and Willems, Robin and Divi, Sai and Hoeijmakers, Martijn and van de Vosse, Frans and Verhoosel, Clemens and Huberts, Wouter},
  title = {Feasibility of large-scale in silico transcatheter aortic valve implantation trials using a fast-to-evaluate model},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2026},
  volume = {25},
  number = {5},
  doi = {10.1007/s10237-026-02136-9}
}
Kostenlos starten →