Personalized biventricular mechanics and sensitivity to model morphology
Biomechanics and Modeling in Mechanobiology · 2026-10 · 25 (5)
DOI: 10.1007/s10237-026-02127-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 22.09.2026. Verfasst von Aaron L Brown und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Stanford University, Stanford, CA, USA. Hauptthemen laut MEDLINE: Models, Cardiovascular, Heart Ventricles, Precision Medicine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 169 Literaturangaben. Gefördert von: NIH HHS, National Science Foundation, American Heart Association.
Abstract (Originalsprache)
We present a computational framework for patient-specific modeling of biventricular (BiV) mechanics based on standard clinical data, including electrocardiogram (ECG), cuff blood pressure, and ECG-gated computed tomography angiography (CTA) imaging. The model is coupled to a closed-loop lumped-parameter network (LPN) circulatory model and incorporates rule-based fiber architecture, as well as spatially varying epicardial boundary conditions to approximate surrounding tissue support. Model parameters are personalized through a multistep procedure that sequentially tunes circulatory dynamics, passive mechanics, and active contraction. The resulting personalized BiV model reproduces the clinical hemodynamic targets used during calibration and demonstrates reasonable agreement with image-based myocardial deformation metrics that were not directly included in the parameter-tuning process. We then use this model as a baseline to assess the impact of two commonly used anatomical simplifications: a truncated BiV (t-BiV) model cut at the basal plane and a left ventricle-only (LV) model. With all parameters held fixed, the LV model exhibits similar global pressure/volume behavior compared to the BiV model, despite moderate differences in regional deformation. In contrast, the t-BiV model produces substantial differences from the full BiV baseline in both global function and local myocardial mechanics. While drawn from a single-patient case study, these results demonstrate that anatomical simplifications can substantially affect model outputs, motivating further investigation across larger cohorts, disease states, and model complexity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Stanford University, Stanford, CA, USA.
- Stanford Cardiovascular Institute, Stanford, CA, USA.
- Department of Mechanical Engineering, Kennesaw State University, Marietta, GA, USA.
- Pasteur Labs, Brooklyn, NY, USA.
- Department of Mechanical Engineering and Materials Science, Washington University, St. Louis, MO, USA.
- Department of Radiology, Stanford University, Stanford, CA, USA.
Förderung
- NIH HHS
- National Science Foundation
- American Heart Association
- National Institutes of Health
Zitieren
APA
Brown, A. L., Shi, L., Salvador, M., Kong, F., Ennis, D. B., Chen, I., Vedula, V., & Marsden, A. L. (2026). Personalized biventricular mechanics and sensitivity to model morphology. Biomechanics and Modeling in Mechanobiology, 25(5). https://doi.org/10.1007/s10237-026-02127-w
Vancouver
Brown AL, Shi L, Salvador M, Kong F, Ennis DB, Chen I, et al. Personalized biventricular mechanics and sensitivity to model morphology. Biomechanics and Modeling in Mechanobiology. 2026;25(5). doi:10.1007/s10237-026-02127-w
BibTeX
@article{Brown2026,
author = {Brown, Aaron L and Shi, Lei and Salvador, Matteo and Kong, Fanwei and Ennis, Daniel B and Chen, Ian and Vedula, Vijay and Marsden, Alison L},
title = {Personalized biventricular mechanics and sensitivity to model morphology},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
volume = {25},
number = {5},
doi = {10.1007/s10237-026-02127-w}
}
EUVIMED