EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation

Christopher J Colloca, Robert Gunzburg

Biomechanics and Modeling in Mechanobiology · 2026-10 · 25 (5)

DOI: 10.1007/s10237-026-02126-x ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 23.09.2026. Verfasst von Christopher J Colloca und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology, College of Health Solutions, Arizona State University, Phoenix, AZ, 85004, USA. ccolloca@asu.edu. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Models, Biological, Manipulation, Spinal. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: International Spine Research Foundation, CBP Nonprofit Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Previously published 5-DOF and 21-DOF lumped-parameter models of the human lumbar spine predict displacement responses to posteroanterior (PA) forces, yet neither has been validated against in vivo frequency response function (FRF) data. This study compared model-predicted driving-point compliance spectra to in vivo experimental data and estimated patient-specific mechanical properties through inverse analysis. Triaxial bone-pin accelerometers were mounted to the L2 and L4 spinous processes of two patients undergoing lumbar decompression surgery. An Impulse iQ instrument delivered 178 controlled impulses at the L3 spinous process across six conditions. Driving-point compliance FRFs were computed using the H1 spectral estimator. Patient-specific PA stiffness and damping ratios were estimated via coherence-weighted logarithmic least-squares optimization. Both patients exhibited a dominant first compliance resonance near 49 Hz, consistent with the 5-DOF prediction of 46 Hz (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lumbar VertebraeModels, BiologicalManipulation, SpinalHumansComplianceBiomechanical PhenomenaReproducibility of ResultsFemale

Stichwörter der Autor:innen

ComplianceFrequency response functionInverse analysisLumbar spineLumped-parameter modelPatient-specific modelingSpinal manipulation

Autor:innen und Institutionen

  • Department of Kinesiology, College of Health Solutions, Arizona State University, Phoenix, AZ, 85004, USA. ccolloca@asu.edu.
  • Cavell Spine Centre, Edith Cavell Hospital, Brussels, Belgium.

Förderung

  • International Spine Research Foundation
  • CBP Nonprofit Inc

Zitieren

APA

Colloca, C. J., & Gunzburg, R. (2026). Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation. Biomechanics and Modeling in Mechanobiology, 25(5). https://doi.org/10.1007/s10237-026-02126-x

Vancouver

Colloca CJ, Gunzburg R. Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation. Biomechanics and Modeling in Mechanobiology. 2026;25(5). doi:10.1007/s10237-026-02126-x

BibTeX
@article{Colloca2026,
  author = {Colloca, Christopher J and Gunzburg, Robert},
  title = {Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2026},
  volume = {25},
  number = {5},
  doi = {10.1007/s10237-026-02126-x}
}
Kostenlos starten →