EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Interface geometry governs probe insertion mechanics and electrode deviation in layered brain-mimicking phantoms for deep brain stimulation

Siyu Chen, Chengyuan Wu, Ethan Anders, Rungun Nathan, Olivia M Bailey, Qifu Wang, Curtis L Johnson, Qianhong Wu iD

Biomechanics and Modeling in Mechanobiology · 2026-10 · 25 (5)

DOI: 10.1007/s10237-026-02122-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 16.09.2026. Verfasst von Siyu Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cellular Biomechanics and Sports Science Laboratory, Villanova University, Villanova, PA, USA. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Phantoms, Imaging, Brain. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Parkinson’s disease (PD) is a progressive neurological disorder often treated with Deep Brain Stimulation (DBS), a surgical procedure that involves implanting electrodes to improve motor function. Accurate electrode placement is critical for treatment efficacy but can be influenced by tissue deformation, insertion forces, and the mechanical properties of brain tissue. In this study, we investigated the role of layer interface angle as a controlled biomechanical factor affecting insertion forces and electrode deviation. A two-layer agar gel phantom was constructed to produce a prescribed stiffness transition between a lower-stiffness and a higher-stiffness gel layer, and its small-amplitude dynamic shear-stiffness contrast was characterized using magnetic resonance elastography (MRE) at 100 Hz. A stage-wise analytical model was formulated to describe the Z-direction axial force–depth response $${F}_{z}\left(z\right)$$ F z z during indentation, fracture, relaxation, and frictional sliding, and a hybrid physics-guided residual neural network (PGNN) was explored as a secondary residual-correction approach for the remaining axial-force model discrepancies. The lateral interface-force change $${F}_{iy}$$ F iy was obtained directly from the measured Y-direction force signal, while electrode deviation was quantified in a separate series of phantom experiments. Insertion experiments at interface angles of 0°, 15°, 30°, 45°, 60°, and 75° demonstrated that the lateral (Y-direction) interface force increased from 0.886 mN at 0° to 7.72 mN at 75°. For the deviation analysis, the mean value of the 0° group was defined as the zero reference; relative to this baseline, the largest group mean deviation was 0.0529 mm at 75°. These findings highlight the role of interface geometry in probe trajectory stability and provide a mechanistic baseline for future studies of probe insertion in two-layer media.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationPhantoms, ImagingBrainElectrodesBiomechanical PhenomenaHumansElasticity Imaging Techniques

Stichwörter der Autor:innen

BiomechanicsDeep brain stimulationElectrode deviationMagnetic resonance elastographyProbe insertionTissue interface

Autor:innen und Institutionen

  • Cellular Biomechanics and Sports Science Laboratory, Villanova University, Villanova, PA, USA.
  • Department of Mechanical Engineering, Villanova University, Villanova, PA, USA.
  • Department of Neurological Surgery, Thomas Jefferson University, Philadelphia, PA, USA.
  • Department of Radiology, Jefferson Magnetic Resonance Imaging Center, Thomas Jefferson University, Philadelphia, PA, USA.
  • Pennsylvania State University Berks, Reading, PA, USA.
  • Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.

ORCID-Profile: Qianhong Wu

Förderung

  • National Science Foundation

Zitieren

APA

Chen, S., Wu, C., Anders, E., Nathan, R., Bailey, O. M., Wang, Q., Johnson, C. L., & Wu, Q. (2026). Interface geometry governs probe insertion mechanics and electrode deviation in layered brain-mimicking phantoms for deep brain stimulation. Biomechanics and Modeling in Mechanobiology, 25(5). https://doi.org/10.1007/s10237-026-02122-1

Vancouver

Chen S, Wu C, Anders E, Nathan R, Bailey OM, Wang Q, et al. Interface geometry governs probe insertion mechanics and electrode deviation in layered brain-mimicking phantoms for deep brain stimulation. Biomechanics and Modeling in Mechanobiology. 2026;25(5). doi:10.1007/s10237-026-02122-1

BibTeX
@article{Chen2026,
  author = {Chen, Siyu and Wu, Chengyuan and Anders, Ethan and Nathan, Rungun and Bailey, Olivia M and Wang, Qifu and Johnson, Curtis L and Wu, Qianhong},
  title = {Interface geometry governs probe insertion mechanics and electrode deviation in layered brain-mimicking phantoms for deep brain stimulation},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2026},
  volume = {25},
  number = {5},
  doi = {10.1007/s10237-026-02122-1}
}
Kostenlos starten →