Integrating serial block-face SEM with voxel-based finite element analysis for high-fidelity micromechanical modelling of anisotropic soft tissues: application to human dermis
Biomechanics and Modeling in Mechanobiology · 2026
DOI: 10.1007/s10237-026-02090-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2026. Verfasst von Jia Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: National Centre for Advanced Tribology at Southampton, Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University…. Hauptthemen laut MEDLINE: Finite Element Analysis, Dermis, Models, Biological, Microscopy, Electron, Scanning. Die Arbeit nennt 131 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: µ-VIS X-Ray Imaging Centre at the University of Southampton, part of the National Facility for laboratory-based X-ray CT (nxct.ac.uk), University of Southampton, Roche Diabetes Care GmbH.
Abstract (Originalsprache)
While continuum fibre-reinforced constitutive models of collagen-rich soft tissues incorporate microstructural information via structure tensor invariants, most of their numerical implementations assume spatially uniform fibre orientations. This study examined how spatially heterogeneous orientations, captured by high-resolution imaging and embedded in image-based finite element models, could provide novel mechanistic insights into tissue micromechanics. Serial block-face scanning electron microscopy (SBF-SEM) captured collagen architecture from fresh human skin dermis. Voxel-level 3D fibre orientations were extracted via structure tensor analysis. Voxel-based hexahedral meshes with element-level orientations were implemented in Abaqus/Standard with custom UMATs® user subroutines for invariant-based transversely isotropic hyperelasticity, and compared to classical models with spatially uniform fibre distributions under various loading conditions. Spatial heterogeneity significantly altered micromechanical responses. Under pseudo-homogeneous uniaxial extension aligned with the mean fibre orientation, Models 1A (uniform orientation, no dispersion), 1B (uniform orientation with dispersion), and 1C (spatially heterogeneous orientations) yielded nominal stresses at 44.6% Green–Lagrange strain differing by a factor of four (0.5, 0.8 and 2.1 MPa, respectively). Model 1C's maximum principal logarithmic strain showed a broader range with a secondary peak at 0.5 versus unimodal peaks at 0.3 for Models 1A/B. With a purely quadratic fibre energy, Model 1C recovered exponential-like macroscopic stiffening for fibre moduli of 25–500 MPa, confirming the J-shape arises from microstructural mechanism rather than through fibre material nonlinearity. The methodology delivers quantitative mechanistic insights into dermal micromechanics and generalises to a wide range of soft tissues from cornea and cartilage to arteries and lungs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Centre for Advanced Tribology at Southampton, Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK.
- μ-VIS X-Ray Imaging Centre, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK.
- Bioengineering Science Research Group, Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK.
- National Centre for Advanced Tribology at Southampton, Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK. g.limbert…
- Bioengineering Science Research Group, Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK. g.limbert@soton.ac.uk.
- Laboratory of Biomechanics and Mechanobiology, Division of Biomedical Engineering, Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, 7935, Observatory, South Africa. g.limbert@…
Förderung
- µ-VIS X-Ray Imaging Centre at the University of Southampton, part of the National Facility for laboratory-based X-ray CT (nxct.ac.uk)
- University of Southampton
- Roche Diabetes Care GmbH
Zitieren
APA
Li, J., Katsamenis, O. L., & Limbert, G. (2026). Integrating serial block-face SEM with voxel-based finite element analysis for high-fidelity micromechanical modelling of anisotropic soft tissues: application to human dermis. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-026-02090-6
Vancouver
Li J, Katsamenis OL, Limbert G. Integrating serial block-face SEM with voxel-based finite element analysis for high-fidelity micromechanical modelling of anisotropic soft tissues: application to human dermis. Biomechanics and Modeling in Mechanobiology. 2026. doi:10.1007/s10237-026-02090-6
BibTeX
@article{Li2026,
author = {Li, Jia and Katsamenis, Orestis L and Limbert, Georges},
title = {Integrating serial block-face SEM with voxel-based finite element analysis for high-fidelity micromechanical modelling of anisotropic soft tissues: application to human dermis},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
doi = {10.1007/s10237-026-02090-6}
}
EUVIMED