EUVIMEDEUVIMED entdecken
Crossref

Should perilymph be considered when modeling the lateral semicircular canal?

Manon Blaise, Daniel Baumgartner, Anne Charpiot

Biomechanics and Modeling in Mechanobiology · 2026-06 · 25 (3)

DOI: 10.1007/s10237-026-02086-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 10.06.2026. Verfasst von Manon Blaise und 2 weiteren Autor:innen. Beteiligte Einrichtung: ICube Laboratory UMR 7357 CNRS, University of Strasbourg, Strasbourg, France. manon.blaise@univ-lyon1.fr. Hauptthemen laut MEDLINE: Semicircular Canals, Models, Biological, Perilymph. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Interdisciplinary Thematic Institute HealthTech, GENCI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The inner ear contains a set of sensors that detect head accelerations, and are responsible for our proper balance. Due to its small size and fragility, numerical models are an essential tool to compensate for the lack of direct biomechanical experiments on the inner ear's tissues. In existing models, the surrounding perilymphatic compartment is seldom represented, imposing rigid boundary conditions on the endolymphatic compartment. Using an original 2.5D finite element model of the lateral semicircular canal, we demonstrate that both perilymph dynamics and membranous labyrinth elasticity significantly influence cupula biomechanical behavior (cupula displacement amplitude and von Mises stress distribution). Based on the cupula's time constant, we also propose new viscoelastic law parameters to best describe its behavior. A numerical simulation of a reference clinical test, in which canal rotation was abruptly stopped within 100 ms, was implemented as a stimulus to the models. In the complete model incorporating the perilymph compartment, the cupula exhibited, as expected, a rapid deflection toward the canal followed by a slow return to its straight position. Conversely, in the absence of the perilymphatic compartment, the cupula demonstrated oscillatory-like behavior, deflecting initially slightly toward the canal and then toward the utricle before returning to its straight position. The implications of accounting for the anatomical (i.e., flexible) boundary conditions of the membranous labyrinth are discussed, highlighting their importance for accurately capturing vestibular mechanics and for improving the understanding of related pathophysiological conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Semicircular CanalsModels, BiologicalPerilymphBiomechanical PhenomenaHumansFinite Element AnalysisComputer SimulationStress, MechanicalElasticity

Stichwörter der Autor:innen

Biomechanical modelingCupulaEndolymphFinite elementPerilymphVestibular system

Autor:innen und Institutionen

  • ICube Laboratory UMR 7357 CNRS, University of Strasbourg, Strasbourg, France. manon.blaise@univ-lyon1.fr.
  • ICube Laboratory UMR 7357 CNRS, University of Strasbourg, Strasbourg, France.
  • Department of Otolaryngology (ENT), Head and Neck Surgery, University Hospital of Strasbourg, Strasbourg, France.

Förderung

  • Interdisciplinary Thematic Institute HealthTech
  • GENCI

Zitieren

APA

Blaise, M., Baumgartner, D., & Charpiot, A. (2026). Should perilymph be considered when modeling the lateral semicircular canal?. Biomechanics and Modeling in Mechanobiology, 25(3). https://doi.org/10.1007/s10237-026-02086-2

Vancouver

Blaise M, Baumgartner D, Charpiot A. Should perilymph be considered when modeling the lateral semicircular canal?. Biomechanics and Modeling in Mechanobiology. 2026;25(3). doi:10.1007/s10237-026-02086-2

BibTeX
@article{Blaise2026,
  author = {Blaise, Manon and Baumgartner, Daniel and Charpiot, Anne},
  title = {Should perilymph be considered when modeling the lateral semicircular canal?},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2026},
  volume = {25},
  number = {3},
  doi = {10.1007/s10237-026-02086-2}
}
Kostenlos starten →