A data-driven computational methodology for assessing ventricular ablation procedures
Biomechanics and Modeling in Mechanobiology · 2026-06 · 25 (3)
DOI: 10.1007/s10237-026-02073-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 03.06.2026. Verfasst von Filippo Caruso Lombardi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Gran Sasso Science Institute (GSSI), Viale Luigi Rendina 26, 67100, L'Aquila, Italy. Hauptthemen laut MEDLINE: Computer Simulation, Heart Ventricles, Catheter Ablation, Ablation Techniques. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gran Sasso Science Institute - GSSI.
Abstract (Originalsprache)
Ventricular tachycardia following myocardial infarction is often sustained by complex reentrant circuits that are challenging to characterize and treat using conventional electroanatomical mapping. Computational modeling provides a powerful complementary approach to understanding conduction pathway dynamics more effectively and supporting ablation strategies. Here, we present a reproducible and data-driven clinically guided computational framework for the retrospective analysis of post-infarction ventricular tachycardia and ablation procedures. The method integrates patient-specific electroanatomical mapping data—including local activation times, voltage maps, and electrograms—to build a personalized model that captures both structural and functional remodeling via a viability-based scalar field. A novel calibration procedure is introduced to locally estimate tissue conductivity, enabling accurate reproduction of observed activation patterns. The model is used to simulate arrhythmia inducibility and sustainability, and to retrospectively evaluate the impact of clinical radiofrequency ablation, accounting for lesion size and transmurality. In silico exploration of alternative ablation strategies is also performed to minimize lesion volume while maintaining arrhythmia suppression. The entire workflow is designed for rapid execution using a GPU-accelerated monodomain solver and is fully compatible with existing clinical practices, offering a practical tool for substrate interpretation and patient-specific ablation planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gran Sasso Science Institute (GSSI), Viale Luigi Rendina 26, 67100, L'Aquila, Italy.
- INFN-Laboratori Nazionali del Gran Sasso, Assergi, Italy.
- Department of Engineering, Università Campus Bio-Medico di Roma, Via A. del Portillo 21, 00128, Rome, Italy.
- Department of Cardiology, Sapienza University of Rome, Viale del Policlinico 155, 00161, Rome, Italy.
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161, Rome, Italy.
- Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via A. del Portillo 21, 00128, Rome, Italy.
Förderung
- Gran Sasso Science Institute - GSSI
Zitieren
APA
Caruso Lombardi, F., Crispino, A., Nguyen, B. L., Galea, N., Loppini, A., Filippi, S., Viola, F., & Gizzi, A. (2026). A data-driven computational methodology for assessing ventricular ablation procedures. Biomechanics and Modeling in Mechanobiology, 25(3). https://doi.org/10.1007/s10237-026-02073-7
Vancouver
Caruso Lombardi F, Crispino A, Nguyen BL, Galea N, Loppini A, Filippi S, et al. A data-driven computational methodology for assessing ventricular ablation procedures. Biomechanics and Modeling in Mechanobiology. 2026;25(3). doi:10.1007/s10237-026-02073-7
BibTeX
@article{CarusoLombardi2026,
author = {Caruso Lombardi, Filippo and Crispino, Anna and Nguyen, Bich Lien and Galea, Nicola and Loppini, Alessandro and Filippi, Simonetta and Viola, Francesco and Gizzi, Alessio},
title = {A data-driven computational methodology for assessing ventricular ablation procedures},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
volume = {25},
number = {3},
doi = {10.1007/s10237-026-02073-7}
}
EUVIMED