A multi-compartment homogenized perfusion model for deforming hierarchical vasculature
Biomechanics and Modeling in Mechanobiology · 2026
DOI: 10.1007/s10237-025-02026-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2026. Verfasst von Jannes Hohl und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Mechanics, Computational Mechanics Group, Technical University of Darmstadt, Darmstadt, 64287, Germany. jannes.hohl@tu-darmstadt.de. Hauptthemen laut MEDLINE: Perfusion, Models, Cardiovascular, Blood Vessels, Models, Biological. Die Arbeit nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 European Research Council, Technische Universität Darmstadt.
Abstract (Originalsprache)
The simulation of tissue perfusion based on highly detailed synthetic vasculature that often consists of multiple supplying and draining trees with millions of vascular segments is computationally expensive. Converting highly detailed synthetic vasculature into a homogenized continuum flow representation offers a computationally efficient alternative. In this paper, we investigate such a modeling approach that retains the essential features of potentially deforming hierarchical vascular networks. It is based on multi-compartment homogenization, where each compartment represents homogenized perfusion via a Darcy-type flow model associated with vascular segments at a specific spatial resolution in one individual tree of the network. The compartments are coupled through a pressure-dependent mass exchange, applied in a smeared manner everywhere within the perfusion domain. Key parameters, namely the permeability tensors of each compartment and the intercompartmental perfusion coefficients, are estimated directly from the vascular segments of the synthetic vasculature using averaging techniques. Our approach leverages spectral decomposition and a reduced set of representative vessel segments to balance computational efficiency with physical fidelity. For scenarios involving deformation, such as in a pumping heart or a regenerating liver, we introduce a computationally efficient parameter update based on geometric mapping, avoiding full re-homogenization in nonlinear simulations. We demonstrate the effectiveness and accuracy of the approach for several benchmark examples, including a full-scale multi-compartment liver perfusion simulation that explicitly incorporates three non-intersecting vascular trees, reflecting the hepatic artery, portal vein, and hepatic vein.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Mechanics, Computational Mechanics Group, Technical University of Darmstadt, Darmstadt, 64287, Germany. jannes.hohl@tu-darmstadt.de.
- Institute for Mechanics, Computational Mechanics Group, Technical University of Darmstadt, Darmstadt, 64287, Germany.
Förderung
- H2020 European Research Council
- Technische Universität Darmstadt
Zitieren
APA
Hohl, J., Ebrahem, A., Jessen, E., Ten Eikelder, M. F. P., & Schillinger, D. (2026). A multi-compartment homogenized perfusion model for deforming hierarchical vasculature. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-025-02026-6
Vancouver
Hohl J, Ebrahem A, Jessen E, Ten Eikelder MFP, Schillinger D. A multi-compartment homogenized perfusion model for deforming hierarchical vasculature. Biomechanics and Modeling in Mechanobiology. 2026. doi:10.1007/s10237-025-02026-6
BibTeX
@article{Hohl2026,
author = {Hohl, Jannes and Ebrahem, Adnan and Jessen, Etienne and Ten Eikelder, Marco F P and Schillinger, Dominik},
title = {A multi-compartment homogenized perfusion model for deforming hierarchical vasculature},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
doi = {10.1007/s10237-025-02026-6}
}
EUVIMED