Prediction accuracy of femoral and tibial stress and strain using statistical shape and density model-based finite element models in paediatrics
Biomechanics and Modeling in Mechanobiology · 2025
DOI: 10.1007/s10237-025-02016-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2025. Verfasst von Yidan Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Auckland Bioengineering Institute, The University of Auckland, 70 Symonds Street, Auckland, New Zealand. Hauptthemen laut MEDLINE: Finite Element Analysis, Tibia, Femur, Stress, Mechanical. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Aotearoa Foundation, University of Auckland.
Abstract (Originalsprache)
Computed tomography (CT)-based finite element (FE) models can non-invasively assess bone mechanical properties, but their clinical application in paediatrics is limited due to fewer datasets and models. Statistical Shape-Density Model (SSDM)-based FE models using statistically inferred shape and density have application to predict bone stress and strains; however, their accuracy in children remains unexplored. This study assessed the accuracy of stress–strain distributions estimated from SSDM-based FE models of paediatric femora and tibiae. CT-based FE models used geometry and densities derived from 330 CT scans from children aged 4–18 years. Paediatric SSDMs of the femur and tibia were used to predict bone geometries and densities from participants’ demographics and linear bone measurements. Forces during single-leg standing were estimated and applied to each bone. Stress and strain distributions were compared between the SSDM-based FE models and CT-based FE models, which served as the gold standard. The average normalized root-mean-square error (NRMSE) for Von Mises stress was 6% for the femur and 8% for the tibia across all cases. Principal strains NRMSE ranged from 1.2% to 5.5%. High correlations between the SSDM-based and CT-based FE models were observed, with determination coefficients ranging from 0.80 to 0.96. These results illustrate the potential of SSDM-based FE models for paediatric application, such as personalized implant design and surgical planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Auckland Bioengineering Institute, The University of Auckland, 70 Symonds Street, Auckland, New Zealand.
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand.
- Auckland Bioengineering Institute, The University of Auckland, 70 Symonds Street, Auckland, New Zealand. j.choisne@auckland.ac.nz.
Förderung
- Aotearoa Foundation
- University of Auckland
Zitieren
APA
Xu, Y., Carman, L., Besier, T. F., & Choisne, J. (2025). Prediction accuracy of femoral and tibial stress and strain using statistical shape and density model-based finite element models in paediatrics. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-025-02016-8
Vancouver
Xu Y, Carman L, Besier TF, Choisne J. Prediction accuracy of femoral and tibial stress and strain using statistical shape and density model-based finite element models in paediatrics. Biomechanics and Modeling in Mechanobiology. 2025. doi:10.1007/s10237-025-02016-8
BibTeX
@article{Xu2025,
author = {Xu, Yidan and Carman, Laura and Besier, Thor F and Choisne, Julie},
title = {Prediction accuracy of femoral and tibial stress and strain using statistical shape and density model-based finite element models in paediatrics},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2025},
doi = {10.1007/s10237-025-02016-8}
}
EUVIMED