Determining a musculoskeletal system’s pre-stretched state using continuum–mechanical forward modelling and joint range optimization
Biomechanics and Modeling in Mechanobiology · 2024
DOI: 10.1007/s10237-024-01821-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2024. Verfasst von Okan Avci und 1 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstr. 12, 70569, Stuttgart, Germany. okan.avci@ipa.fraunhofer.de. Hauptthemen laut MEDLINE: Range of Motion, Articular, Models, Biological, Joints. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fraunhofer Internal Program, Bundesministerium für Bildung und Forschung, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
The subject-specific range of motion (RoM) of a musculoskeletal joint system is balanced by pre-tension levels of individual muscles, which affects their contraction capability. Such an inherent pre-tension or pre-stretch of muscles is not measureable with in vivo experiments. Using a 3D continuum mechanical forward simulation approach for motion analysis of the musculoskeletal system of the forearm with 3 flexor and 2 extensor muscles, we developed an optimization process to determine the muscle fibre pre-stretches for an initial arm position, which is given human dataset. We used RoM values of a healthy person to balance the motion in extension and flexion. The performed sensitivity study shows that the fibre pre-stretches of the m. brachialis , m. biceps brachii and m. triceps brachii with $$91\%$$ 91 % dominate the objective flexion ratio, while m. brachiradialis and m. anconeus amount $$7.8\%$$ 7.8 % and $$1.2\%$$ 1.2 % . Within the multi-dimensional space of the surrogate model, 3D sub-spaces of primary variables, namely the dominant muscles and the global objective, flexion ratio, exhibit a path of optimal solutions. Within this optimal path, the muscle fibre pre-stretch of two flexors demonstrate a negative correlation, while, in contrast, the primary extensor, m. triceps brachii correlates positively to each of the flexors. Comparing the global optimum with four other designs along the optimal path, we saw large deviations, e.g., up to 15 $$^{\circ }$$ ∘ in motion and up to 40% in muscle force. This underlines the importance of accurate determination of fibre pre-stretch in muscles, especially, their role in pathological muscular disorders and surgical applications such as free muscle or tendon transfer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstr. 12, 70569, Stuttgart, Germany. okan.avci@ipa.fraunhofer.de.
- Institute of Modelling and Simulation for Biomechanical Systems and Cluster of Excellence for Simulation Technology, University of Stuttgart, Pfaffenwaldring 5a, 70569, Stuttgart, Germany.
Förderung
- Fraunhofer Internal Program
- Bundesministerium für Bildung und Forschung
- Deutsche Forschungsgemeinschaft
- Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA
Zitieren
APA
Avci, O., & Röhrle, O. (2024). Determining a musculoskeletal system’s pre-stretched state using continuum–mechanical forward modelling and joint range optimization. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-024-01821-x
Vancouver
Avci O, Röhrle O. Determining a musculoskeletal system’s pre-stretched state using continuum–mechanical forward modelling and joint range optimization. Biomechanics and Modeling in Mechanobiology. 2024. doi:10.1007/s10237-024-01821-x
BibTeX
@article{Avci2024,
author = {Avci, Okan and Röhrle, Oliver},
title = {Determining a musculoskeletal system’s pre-stretched state using continuum–mechanical forward modelling and joint range optimization},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2024},
doi = {10.1007/s10237-024-01821-x}
}
EUVIMED