Numerical study of ultra-large von Willebrand factor multimers in coagulopathy
Biomechanics and Modeling in Mechanobiology · 2024
DOI: 10.1007/s10237-023-01803-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2024. Verfasst von Nahid Rahmati und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Systems Design Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada. Hauptthemen laut MEDLINE: Blood Coagulation Disorders, von Willebrand Factor. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 91 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
An excessive von Willebrand factor (VWF) secretion, coupled with a moderate to severe deficiency of ADAMTS13 activity, serves as a linking mechanism between inflammation to thrombosis. The former facilitates platelet adhesion to the vessel wall and the latter is required to cleave VWF multimers. As a result, the ultra-large VWF (UL-VWF) multimers released by Weibel-Palade bodies remain uncleaved. In this study, using a computational model based on first principles, we quantitatively show how the uncleaved UL-VWF multimers interact with the blood cells to initiate microthrombosis. We observed that platelets first adhere to unfolded and stretched uncleaved UL-VWF multimers anchored to the microvessel wall. By the end of this initial adhesion phase, the UL-VWF multimers and platelets make a mesh-like trap in which the red blood cells increasingly accumulate to initiate a gradually growing microthrombosis. Although high-shear rate and blood flow velocity are required to activate platelets and unfold the UL-VWFs, during the initial adhesion phase, the blood velocity drastically drops after thrombosis, and as a result, the wall shear stress is elevated near UL-VWF roots, and the pressure drops up to 6 times of the healthy condition. As the time passes, these trends progressively continue until the microthrombosis fully develops and the effective size of the microthrombosis and these flow quantities remain almost constant. Our findings quantitatively demonstrate the potential role of UL-VWF in coagulopathy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Systems Design Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
- Centre for Bioengineering and Biotechnology, University of Waterloo, Waterloo, ON, Canada.
- Department of Systems Design Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada. nmaftoon@uwaterloo.ca.
- Centre for Bioengineering and Biotechnology, University of Waterloo, Waterloo, ON, Canada. nmaftoon@uwaterloo.ca.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Rahmati, N., Keshavarz Motamed, P., & Maftoon, N. (2024). Numerical study of ultra-large von Willebrand factor multimers in coagulopathy. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-023-01803-5
Vancouver
Rahmati N, Keshavarz Motamed P, Maftoon N. Numerical study of ultra-large von Willebrand factor multimers in coagulopathy. Biomechanics and Modeling in Mechanobiology. 2024. doi:10.1007/s10237-023-01803-5
BibTeX
@article{Rahmati2024,
author = {Rahmati, Nahid and Keshavarz Motamed, Pouyan and Maftoon, Nima},
title = {Numerical study of ultra-large von Willebrand factor multimers in coagulopathy},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2024},
doi = {10.1007/s10237-023-01803-5}
}