Biomechanical characterization of tissue types in murine dissecting aneurysms based on histology and 4D ultrasound-derived strain
Biomechanics and Modeling in Mechanobiology · 2023
DOI: 10.1007/s10237-023-01759-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2023. Verfasst von Achim Hegner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Personalized Biomedical Engineering Lab, Frankfurt University of Applied Sciences, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Elastin, Aortic Dissection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Weldon School of Biomedical Engineering at Purdue University, Hugh W. and Edna M. Donnan Fellowship, American Heart Association, Doctoral funding of the Frankfurt University of Applied Sciences.
Abstract (Originalsprache)
Abdominal aortic aneurysm disease is the local enlargement of the aorta, typically in the infrarenal section, causing up to 200,000 deaths/year. In vivo information to characterize the individual elastic properties of the aneurysm wall in terms of rupture risk is lacking. We used a method that combines 4D ultrasound and direct deformation estimation to compute in vivo 3D Green-Lagrange strain in murine angiotensin II-induced dissecting aortic aneurysms, a commonly used mouse model. After euthanasia, histological staining of cross-sectional sections along the aorta was performed in areas where in vivo strains had previously been measured. The histological sections were segmented into intact and fragmented elastin, thrombus with and without red blood cells, and outer vessel wall including the adventitia. Meshes were then created from the individual contours based on the histological segmentations. The isolated contours of the outer wall and lumen from both imaging modalities were registered individually using a coherent point drift algorithm. 2D finite element models were generated from the meshes, and the displacements from the registration were used as displacement boundaries of the lumen and wall contours. Based on the resulting deformed contours, the strains recorded were grouped according to segmented tissue regions. Strains were highest in areas containing intact elastin without thrombus attachment. Strains in areas with intact elastin and thrombus attachment, as well as areas with disrupted elastin, were significantly lower. Strains in thrombus regions with red blood cells were significantly higher compared to thrombus regions without. We then compared this analysis to statistical distribution indices and found that the results of each aligned, elucidating the relationship between vessel strain and structural changes. This work demonstrates the possibility of advancing in vivo assessments to a microstructural level ultimately improving patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Personalized Biomedical Engineering Lab, Frankfurt University of Applied Sciences, Frankfurt am Main, Germany.
- Department of Mechanical Engineering and Industrial Design, School of Engineering, University of Cadiz, Cadiz, Spain.
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, USA.
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, USA.
- Cell and Vascular Mechanics, Goethe University, Frankfurt am Main, Germany.
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, USA. cgoergen@purdue.edu.
Förderung
- Weldon School of Biomedical Engineering at Purdue University, Hugh W. and Edna M. Donnan Fellowship
- American Heart Association
- Doctoral funding of the Frankfurt University of Applied Sciences
- Weldon School of Biomedical Engineering at Purdue University, Ross Fellowship
- Hessian Ministry of Science and the Arts
- Frankfurt University of Applied Sciences
Zitieren
APA
Hegner, A., Cebull, H. L., Gámez, A. J., Blase, C., Goergen, C. J., & Wittek, A. (2023). Biomechanical characterization of tissue types in murine dissecting aneurysms based on histology and 4D ultrasound-derived strain. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-023-01759-6
Vancouver
Hegner A, Cebull HL, Gámez AJ, Blase C, Goergen CJ, Wittek A. Biomechanical characterization of tissue types in murine dissecting aneurysms based on histology and 4D ultrasound-derived strain. Biomechanics and Modeling in Mechanobiology. 2023. doi:10.1007/s10237-023-01759-6
BibTeX
@article{Hegner2023,
author = {Hegner, Achim and Cebull, Hannah L and Gámez, Antonio J and Blase, Christopher and Goergen, Craig J and Wittek, Andreas},
title = {Biomechanical characterization of tissue types in murine dissecting aneurysms based on histology and 4D ultrasound-derived strain},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2023},
doi = {10.1007/s10237-023-01759-6}
}
EUVIMED