A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth
Biomechanics and Modeling in Mechanobiology · 2024
DOI: 10.1007/s10237-023-01757-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2024. Verfasst von Kaihong Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Imperial College London, London, UK. Hauptthemen laut MEDLINE: Thrombosis, Aortic Dissection, Biological Phenomena. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical Engineering, Imperial College London, London, UK.
- Regional Vascular Unit, St Mary's Hospital, Imperial College Healthcare National Health Service Trust, Imperial College London, London, UK.
- Department of Chemical Engineering, Imperial College London, London, UK. yun.xu@imperial.ac.uk.
ORCID-Profile: Chlöe H Armour, Xiao Yun Xu
Zitieren
APA
Wang, K., Armour, C. H., Gibbs, R. G. J., & Xu, X. Y. (2024). A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-023-01757-8
Vancouver
Wang K, Armour CH, Gibbs RGJ, Xu XY. A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth. Biomechanics and Modeling in Mechanobiology. 2024. doi:10.1007/s10237-023-01757-8
BibTeX
@article{Wang2024,
author = {Wang, Kaihong and Armour, Chlöe H and Gibbs, Richard G J and Xu, Xiao Yun},
title = {A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2024},
doi = {10.1007/s10237-023-01757-8}
}
EUVIMED