Fachartikel in der Zeitschrift Journal of the Association for Research in Otolaryngology, online erschienen am 30.01.2017. Verfasst von Olivier Macherey und 3 weiteren Autor:innen. Beteiligte Einrichtung: Aix Marseille Université, CNRS, Centrale Marseille, LMA, 4 Impasse Nikola Tesla CS 40006, F-13453, Marseille Cedex 13, France. macherey@lma.cnrs-mrs.…. Hauptthemen laut MEDLINE: Auditory Threshold, Cochlear Implants, Loudness Perception. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Medical Research Council, Agence Nationale de la Recherche, Centre National de la Recherche Scientifique.
Abstract (Originalsprache)
Most cochlear implants (CIs) activate their electrodes non-simultaneously in order to eliminate electrical field interactions. However, the membrane of auditory nerve fibers needs time to return to its resting state, causing the probability of firing to a pulse to be affected by previous pulses. Here, we provide new evidence on the effect of pulse polarity and current level on these interactions. In experiment 1, detection thresholds and most comfortable levels (MCLs) were measured in CI users for 100-Hz pulse trains consisting of two consecutive biphasic pulses of the same or of opposite polarity. All combinations of polarities were studied: anodic-cathodic-anodic-cathodic (ACAC), CACA, ACCA, and CAAC. Thresholds were lower when the adjacent phases of the two pulses had the same polarity (ACCA and CAAC) than when they were different (ACAC and CACA). Some subjects showed a lower threshold for ACCA than for CAAC while others showed the opposite trend demonstrating that polarity sensitivity at threshold is genuine and subject- or electrode-dependent. In contrast, anodic (CAAC) pulses always showed a lower MCL than cathodic (ACCA) pulses, confirming previous reports. In experiments 2 and 3, the subjects compared the loudness of several pulse trains differing in current level separately for ACCA and CAAC. For 40 % of the electrodes tested, loudness grew non-monotonically as a function of current level for ACCA but never for CAAC. This finding may relate to a conduction block of the action potentials along the fibers induced by a strong hyperpolarization of their central processes. Further analysis showed that the electrodes showing a lower threshold for ACCA than for CAAC were more likely to yield a non-monotonic loudness growth. It is proposed that polarity sensitivity at threshold reflects the local neural health and that anodic asymmetric pulses should preferably be used to convey sound information while avoiding abnormal loudness percepts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Aix Marseille Université, CNRS, Centrale Marseille, LMA, 4 Impasse Nikola Tesla CS 40006, F-13453, Marseille Cedex 13, France. macherey@lma.cnrs-mrs.fr.
- MRC Cognition and Brain Sciences Unit, 31 Chaucer Road, Cambridge, CB2 7EF, UK.
- Aix Marseille Université, CNRS, Centrale Marseille, LMA, 4 Impasse Nikola Tesla CS 40006, F-13453, Marseille Cedex 13, France.
- Department of Pediatric Otolaryngology and Neck Surgery, La Timone Children's Hospital, Aix Marseille Université, 264 rue Saint-Pierre, 13385, Marseille Cedex 5, France.
Förderung
- Medical Research Council
- Agence Nationale de la Recherche
- Centre National de la Recherche Scientifique
Zitieren
APA
Macherey, O., Carlyon, R. P., Chatron, J., & Roman, S. (2017). Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant Users. Journal of the Association for Research in Otolaryngology, 18(3), 513-527. https://doi.org/10.1007/s10162-016-0614-4
Vancouver
Macherey O, Carlyon RP, Chatron J, Roman S. Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant Users. Journal of the Association for Research in Otolaryngology. 2017;18(3):513-527. doi:10.1007/s10162-016-0614-4
BibTeX
@article{Macherey2017,
author = {Macherey, Olivier and Carlyon, Robert P and Chatron, Jacques and Roman, Stéphane},
title = {Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant Users},
journal = {Journal of the Association for Research in Otolaryngology},
year = {2017},
volume = {18},
number = {3},
pages = {513--527},
doi = {10.1007/s10162-016-0614-4}
}
EUVIMED