Docking optimization for right hemicolectomy with complete mesocolon excision (CME) with HUGO™ robotic system: the “Gemelli configuration”
Techniques in Coloproctology · 2026-12 · 30 (1)
DOI: 10.1007/s10151-026-03316-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Techniques in Coloproctology, online erschienen am 01.05.2026. Verfasst von Claudio Fiorillo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Digestive Surgery Unit, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168, Rome, Italy. Hauptthemen laut MEDLINE: Colectomy, Mesocolon, Robotic Surgical Procedures, Laparoscopy. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Laparoscopic complete mesocolic excision (CME) during right hemicolectomy is a complex procedure. The introduction of robotic-assisted surgery has improved dexterity, three-dimensional (3D) visualization, and surgeon ergonomics. However, for the modular HUGO™ Robotic-Assisted Surgery (RAS) system, experience with CME is limited, and the standard docking configuration for right hemicolectomy presents many disadvantages.
Methods
We developed a modified docking strategy (the “Gemelli configuration”) specifically designed to optimize robotic right hemicolectomy with CME using the HUGO™ RAS platform. This setup provides improved instruments triangulation and reduced robotic arm interference. The technique was applied in two consecutive cases.
Results
Both procedures were completed fully robotically with a single docking, without arm collisions or the need for repositioning. Compared with the standard setup, the Gemelli configuration yields enhanced visualization of the mesenteric axis and vascular pedicles and improved access to the transverse mesocolon.
Conclusions
The “Gemelli configuration” represents a safe, simple, and reproducible docking strategy for performing right hemicolectomy with CME using the HUGO™ RAS system. Further validation in larger patient series is warranted to confirm these preliminary benefits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Digestive Surgery Unit, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168, Rome, Italy.
- Università Cattolica del Sacro Cuore di Roma, 00168, Rome, Italy.
- Digestive Surgery Unit, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168, Rome, Italy. davide.desio@policlinicogemelli.it.
Zitieren
APA
Fiorillo, C., De Sio, D., Biffoni, B., Taglioni, F., Menghi, R., Tortorelli, A. P., Alfieri, S., & Quero, G. (2026). Docking optimization for right hemicolectomy with complete mesocolon excision (CME) with HUGO™ robotic system: the “Gemelli configuration”. Techniques in Coloproctology, 30(1). https://doi.org/10.1007/s10151-026-03316-6
Vancouver
Fiorillo C, De Sio D, Biffoni B, Taglioni F, Menghi R, Tortorelli AP, et al. Docking optimization for right hemicolectomy with complete mesocolon excision (CME) with HUGO™ robotic system: the “Gemelli configuration”. Techniques in Coloproctology. 2026;30(1). doi:10.1007/s10151-026-03316-6
BibTeX
@article{Fiorillo2026,
author = {Fiorillo, Claudio and De Sio, Davide and Biffoni, Beatrice and Taglioni, Flavia and Menghi, Roberta and Tortorelli, Antonio Pio and Alfieri, Sergio and Quero, Giuseppe},
title = {Docking optimization for right hemicolectomy with complete mesocolon excision (CME) with HUGO™ robotic system: the “Gemelli configuration”},
journal = {Techniques in Coloproctology},
year = {2026},
volume = {30},
number = {1},
doi = {10.1007/s10151-026-03316-6}
}
EUVIMED