EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Quantification of indocyanine-green-enhanced fluorescence with spectrophotometry (O2C®) in low anterior rectal resection: A prospective study

I Darwich, S Demirel-Darwich, C Weiss, F Willeke

Techniques in Coloproctology · 2025

DOI: 10.1007/s10151-024-03062-7 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Techniques in Coloproctology, 2025. Verfasst von I Darwich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany. Ibrahim@darwich.net. Hauptthemen laut MEDLINE: Indocyanine Green, Proctectomy, Rectal Neoplasms. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Despite spectacular visuals and the seemingly convincing rationale of using indocyanine-green-enhanced fluorescence in assessing bowel perfusion during colorectal resections, a lingering sense of subjectivity remains in the challenge of quantifying this fluorescence. This prospective study analyzed the application of O2C® spectrophotometry to quantify zones of fluorescence on the large bowel during low anterior resection. Materials and methods Patients receiving a low anterior resection for cancer of the mid- and lower rectum were enrolled in this observational prospective study between February 2020 and December 2022. O2C® blood-flow measurement was performed at three different zones of fluorescence intensity (optimal [O], sufficient [S], and absent [A]), visualized at the designated and already skeletonized site of colon transection. The primary end point was to assess whether the O2C® flow value exceeds 164 arbitrary units (AU) at the zone of optimal fluorescence. The secondary objective was to assess whether there were statistically significant differences in flow parameters between the three zones, thus confirming reproducibility of measurements.

Results

A total of 40 patients were enrolled in this study. Of these, 38 patients remained for statistical analysis with regard to O2C® measurement of the fluorescence zones. The O2C® flow parameter measured at the zone of optimal fluorescence was greater than 164 AU in all cases (100%, p < 0.0001). There were statistically significant differences in flow parameters measured at the three different zones of fluorescence (O-S: p < 0.0001; O-A: p < 0.0001; S-A: p = 0.0023).

Conclusion

This study proves the feasibility and reproducibility of quantifying zones of indocyanine green (ICG)-enhanced fluorescence on the bowel. All O2C® flow measurements that were collected at the zone of optimal fluorescence exceeded 164 AU, thereby adding more evidence to this value as a suggested cut-off parameter in terms of bowel perfusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Indocyanine GreenProctectomyRectal NeoplasmsAgedAged, 80 and overFemaleHumansMaleMiddle AgedColoring AgentsFluorescenceProspective StudiesRectumReproducibility of ResultsSpectrophotometry

Stichwörter der Autor:innen

Anastomotic leakBowel perfusionCold steel testColic marginal arteryFluorescenceICGLow anterior resectionO2C®

Substanzen

Coloring AgentsIndocyanine Green

Autor:innen und Institutionen

  • Department of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany. Ibrahim@darwich.net.
  • Department of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany.
  • Department of Medical Statistics, Biomathematics, and Information Processing at the University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.

Zitieren

APA

Darwich, I., Demirel-Darwich, S., Weiss, C., & Willeke, F. (2025). Quantification of indocyanine-green-enhanced fluorescence with spectrophotometry (O2C®) in low anterior rectal resection: A prospective study. Techniques in Coloproctology. https://doi.org/10.1007/s10151-024-03062-7

Vancouver

Darwich I, Demirel-Darwich S, Weiss C, Willeke F. Quantification of indocyanine-green-enhanced fluorescence with spectrophotometry (O2C®) in low anterior rectal resection: A prospective study. Techniques in Coloproctology. 2025. doi:10.1007/s10151-024-03062-7

BibTeX
@article{Darwich2025,
  author = {Darwich, I and Demirel-Darwich, S and Weiss, C and Willeke, F},
  title = {Quantification of indocyanine-green-enhanced fluorescence with spectrophotometry (O2C®) in low anterior rectal resection: A prospective study},
  journal = {Techniques in Coloproctology},
  year = {2025},
  doi = {10.1007/s10151-024-03062-7}
}
Kostenlos starten →